Frequency counter-timer F5041 (F-5041, F 5041)
 
Frequency counter-timer F5041 is designed to measure frequency and period of oscillations, pulse width, frequency ratio, the electric pulses, as well as a frequency divider and oscillator frequency model.
 
Technical characteristics of the devices frequency-chronometers F5041:
 
The main technical characteristics of the device frequency-timer F5041 are listed in Table 1;
 
Table 1 Main technical characteristics of the device frequency-timer F5041
Instrument parameter Measuring range Maximum permissible relative error The input voltage range
The frequency of oscillations 0.1 Hz to 10 MHz ± (δo +1 / ftizm) 0.1 30Vsr. Sq. m. (March 10 Hz to 10 7 Hz)
The period of oscillations 0.1 Hz-1 MHz ± [δo + (1 / n) (a + To / T)] 1 30Vsr.kv.
1 30Vampl
The pulse duration 1mks-1c ± [δo + (k + To + (1/Sf +1 / Sc)) Δ / τ] 1 30Vampl
Time interval 10mks-10 4 ± [δo + (To +0,5 ms) / t] 3 30ampl
The frequency ratio From 1:1 to 10 6: 1 ± (1 / n) (a + f2/f1) 1 30Vsr.kv.
1 30Vampl
Account or summation of electrical impulses Before filling the counter ± (1 / N) l 1 30Vampl
Note: δo - the largest allowable value of additional error source reference frequency; f - frequency-measuring device chronometer F5041 Frequency, Hz tmeas - time of measurement, and a = 3.10 3 measurement periods of sinusoidal signals, and a = 0 for the measurement period pulse signals; That - between fill-frequency (time stamp), ms, T - measured period, ms; k = 0,5 ms when using an ac amplifier; k = 10mks using a dc amplifier, Sf - steepness frequency-measuring device Chronometer F5041 pulses V / us, Sc - Slope of measured pulse V / ms; Δ = 1B - sensitivity shaping circuit; τ - measured pulse duration, ms; t - measures the elapsed time, ms; f1 - the highest frequency of the measured ratio , Hz; f2 - the lowest frequency of the measured ratio, Hz; n - the number of measured periods or multiplier frequency ratio; N - measured by the number of pulses; l = 1 for pulse counting, or the number of dimensions in the summation;
 
The highest permissible value of the relative error frequency oscillator frequency device δo max-timer F5041 does not exceed:
- 1.10 -7 - in the first 10 days after setting;
- 1.10 -8 - during the day;
The relative value of the average daily volatility δo device frequency-timer F5041 - less than 3.10 -8;
Error of the nominal value of δo - no more than ± 5.10 -8;
Temperature coefficient of frequency - no more than ± 3.10 -9 to -1;
Up time-frequency device chronometer F5041 - no more than 2 hours;
Frequency counter has an output following frequencies: 10 -2 Hz, 10 -1 Hz 1Hz, 10Hz, 10, 2 Hz, 10 2 Hz, 2.5 Hz, 10 3, 10 4 Hz, 5.10 Hz, 4, 10, 5 Hz; June 10 Hz, 10 7 Hz;
The amplitude of the output signals of the device frequency-timer F5041:
- Not less than 3V - for frequencies from 10 -2 Hz to 10 5 Hz;
- Not less than 1.2 - for frequencies between 10 and 6 Hz to 10 7 Hz,
at a load of 10 ohms;
Time frequency measurement device frequency-timer F5041 - 10 -2 s, 10 -1, 1 s, 10 s, 10, 2;
Frequency counter measures the duration of one period and the average duration of 10, 10, 2, March 10, April 10 periods;
The resolution of the pulse counting - 0.2 ms pulse duration 0.1 ms and 1mks;
Operation mode frequency-timer F5041 - automatic, manual, remote;
Time display of measurement results - from 0.5 to 5 seconds;
Frequency counter allows for the possibility of using it as a frequency divider with a division factor of 10, February 10, March 10, April 10 in the frequency range of 0.1 Hz to 10 6 Hz;
In devices frequency-chronometers F5041 has an output of measurement results in BCD parallel-serial code 8-4-2-1:
- The signal amplitude from 2.4 V to 5.25 V - for a logical "1";
- The signal amplitude from 0 V to 0.4 V - for a logical "0";
Power supply frequency-timer F5041 - AC, 50 Hz ± 1 Hz 220V with a tolerance of +10% to -15%;
Power consumption - no more than 60 V · A;
Dimensions of the device frequency-timer F5041 - 490h130h380mm;
Weight - 12 kg;
Time to failure - at least 5250 hours;
The manufacturer guarantees that the quality of the device frequency-timer F5041 technical requirements specifications provided the customer terms and conditions of storage, transportation, installation, operation, and its specified operational documentation.