Electrical measuring instruments >> combination devices

F4313

6 600 RUB
1 600 UAH
available:
5 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.

    Combined portable device F4313

    Also, this device can be called: F 4313, F-4313.
 
    F4313 portable device combination designed to measure current and DC voltage, rms voltage and current AC pure sine wave, DC resistance and AC voltage transmission level.
    Measurement range - from 500 ohms to 5000 ohms.
    Internal voltage electrochemical power source - from 3.8 V to 4.8 V.
    Voltage of the external power source to the detection limit of 5000 ohm - from 34 V to 44 V.
 
    F4313 devices are equipped with a magneto system combined with a movable frame on extensions. Rectifier system, semiconductor rectifiers with arrow pointer with unilateral uneven scales when measuring voltage and current, DC resistance and capacitance and bilateral asymmetric uneven scales in the measurement of the transmission level.

    Specifications F4313:
    Protection scheme - from 2.6 V to 3.5 V.

    Limits of measurement:
    - The power of AC and DC - 0.06 mA, 0.12 mA, 0.6 mA, 3 mA, 12 mA, 60 mA, 300 mA, 1.2 A, 6 A;
    - DC and AC - 0.06 V, 0.3 V, 1.2 V, 6 V, 30 V, 120 V, 300 V, 600 V, 1200 V;
    - DC resistance - 300 ohms, 5 ohms, 50 ohms, 500 ohms, 5 MW;
    - AC voltage transmission level - from -20 dB to +3 dB.

    Accuracy:
    - DC current - ± 1,5%;
    - DC voltage - ± 1,5%;
    - AC power - ± 2,5%;
    - AC voltage - ± 2,5%;
    - AC voltage transmission level - ± 2,5%.

    Current full deviation when the voltage, the voltage drop at the terminals when the F4313 devices amperage and current consumption of electrochemical sources listed in Table 1.
 
    Table 1
Type of current
Limits of measurement
Voltage drop in
Full-scale deflection current, mA
Current consumption from elektrohimichekih sources mA
DC and AC (50 Hz)
12 mA
60 mA
0.35 V
At 0.40
-
-
-
-
Permanent
300 mA
1.2 A
A 6
300 Ohm
5 ohms
50K
500 k
5000 ohms
0.45
0.50 V
+1.00
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.14 mA
0,014 mA
0,003 mA
0,002 mA
0.001 mA
DC and AC (50 Hz)
0.06 mA
0.12 mA
0.60 mA
3 mA
0,15
At 0.25
0.30 V
0.32 In
-
-
-
-
-
-
-
-
DC and AC (50 Hz)
from 0.06 V to 600 V
1200
from 0.06 V to 600 V
300
600
1200
-
52 mA
104 mA
54 mA
60 mA
70 mA
150 mA
-
 
    Frequency range of the device is indicated in Table 2 combined.

    Table 2
Ranges
Frequency range, Hz
normal
Working
from 0.06 mA to 6000 mA
from 0.06 V to 30 V
from 45 Hz to 5000 Hz
from 5,000 Hz to 10,000 Hz
120
300
600
1200
45 Hz to 2000 Hz
from 45 Hz to 500 Hz
from 45 Hz to 100 Hz
45 Hz to 60 Hz
from 2000 Hz to 5000 Hz
from 500 to 1000 Hz
from 100 Hz to 200 Hz
from 60 Hz to 100 Hz
 
    Time for reading devices - no more than 4 seconds.
    Dimensions - 225h120h90 mm.
    Weight of the device combined - 2.0 kg.
    Operating conditions:
 
    Ambient temperature - +10 ° C to +40 ° C.
    Relative humidity at +25 ° C - 80%.
    Atmospheric pressure - from 86 kPa to 106 kPa (650 mm Hg. Art. 800 mm Hg. Tbsp.)

Photos: F4313

F4313 device image.
F4313 device image.
F4313 view panel of the device.
F4313 view panel of the device.
F4313 side view.
F4313 side view.
F4313 side view.
F4313 side view.
F4313 side view.
F4313 side view.
F4313 bottom view.