Voltmeter EV1606 (EV 1606, EV-1606, eb1606, EV1606, eb 1606, eb-1606)

Voltmeter EV1606 is designed to measure the voltage in the networks of ship power systems.
Accuracy class - 2.5;
Vibration-resistant, shock-resistant, leakproof.
Technical characteristics of the devices voltmeters EV1606:
- Ambient temperature from -40 º C to +60 º C;
- Relative humidity up to 100% at 35 º C;
- Ranges and how your device EV1606 listed in Table 1;
 
Table 1: Ranges and means connecting a voltmeter
Measurement range
Nominal frequency
The connection method
0V-30V, 0V-50V, 0V-150V, 0V-250V, 0V-500V
50Hz
Direct
0V-450V
Voltage transformer 380/127
0V-50V, 0V-150V, 0V-250V, 0V-500V
400Hz
Direct

- Maximum permissible error of the instrument EV1606 is ± 1,5% of full scale range;
- Measuring range from 15% to 100% range of indications;
- The limit of additional error caused by:
- Changes in the ambient temperature of the normal 20 º C ± 5 º C to any temperature from -40 º C to +60 º C for every 10 º C of temperature change is equal to 50% of accuracy class designation;
- The influence of external magnetic field, a DC voltage of 0.4 kA / m is ± 1%;
- Changes in the operating position (tilt) of the device EV1606 from normal in any direction up to 45 º, is ± 1%;
- Installation of the instrument panel on a ferromagnetic thickness of 2 mm ± 0,5 mm, or the influence of adjacent unit must be equal to ± 0,5%;
- Basic and additional error EV1606 device intended for connection to external voltage transformers, normalized without error voltage transformers;
- Proper use of voltmeters, designed to connect via voltage transformers, the voltage value corresponding to the final value of the measuring range and the normal frequency does not exceed 10VA;
- Dielectric strength at an ambient temperature of 20 º C ± 5 º C and a relative humidity of 80% - 2kV;
- Insulation resistance of electrical circuits against the housing at an ambient temperature of 20 º C ± 5 º C and 80% relative humidity of at least 50 MW;
- Response time showing the device is less than 3 seconds;
- The length of the instrument scale EV1606 180mm ± 8 mm;
- The angle of the scale - 230 º ± 10 º;
- Dimensions - 145h231h95mm;
- Weight of the device - no more than 2,7 kg.