Electrical measuring instruments >> measuring transducers >> transducers EP

EP8527

For order is possible effectively delivery of any quantity.
    Measuring transducer EP8527 AC and AC voltage.
    Also this device can be called: EP-8527, EP 8527, EP8527, EP-8527, EP 8527, ЄP8527, ЄP-8527, ЄP 8527, ep8527, ep-8527, ep 8527.
    Measuring transducer EP8527 12 has modifications depending on the type and magnitude of the transformed signal.
    Measuring transducer EP8527 / 1, 2, 12, 16, 17 - a device for converting AC line voltage to a standardized operating mode AC output.
    EP8527/4-11 measuring transducer - a device for    linear AC conversion modes overload uniform AC output.
    Measuring transducer EP8527/14, 15, 18, 19 - a device for converting alternating current line-operate and congestion in a standardized output AC signal.
    Measuring transducer EP8527 / 3, 13 - a device for converting linear voltage AC operation modes and modes of congestion in a standardized output AC signal.
    Devices EP8527 / 1, 2, 4-12 is monaural products. The number of channels in type converters 3, 13-19 from one to four (on request).
    Specifications EP8527

    Feature types of devices EP8527 1, 2, 4-12 is that they are single-channel. Type converters 3, 13-19 have from one to four channels (on request).
    Measuring converters are often used in the information-measuring system for transmitting information to the input of high-speed digital oscilloscope (for recording and analysis of emergency operation), do not require an additional power supply.
    In the devices is a function of galvanic isolation between the input and output circuits for each channel, as well as any link between the chains and the chains of the other channels.

    Measuring range input: 0-5A, 0-400V.
    Measuring range Output: 0-5, 0-5 -6.5, 0-5 , 100 mA.

    Accuracy classes in operation span the input signal (in overload the input of the measuring range) for various modifications of the inverter EP8527:
    - Types 1, 2, 12, 16, 17 - 1.0;
    - Types 3, 13 - 0.25 (0.5);
    - Types 4-11 - (2.0);
    - Types 14, 15 - 0.25 (0.5);
    - Types 18, 19 - 1.0 (2.0).
    The range of the input and output devices from 45 to 55Hz.

For speed measurement limits of permissible basic error as a percentage of the value of the normalizing input signal are shown in Table 1.


    Table 1. Limits of reduced error.

Modification of the transducer
EP8527
Limits of basic error,%
In the operation mode input range measurements
In the overloading of the measuring range input
1, 2, 12, 16, 17
± 1,0%
-
3, 13
± 0,25%
± 0,5%
4-11
-
± 2,0%
14, 15
± 0,25%
± 0,5%
18, 19
± 1,0%
± 2,0%

    Table 2 according to the modification of the converter fed characteristics of input and output signals, the load impedance.

    Table 2-1. Har akteristiki input and output signals, the resistance of the load.
Modif pecifications device
The range of measurement input
Rated
mv Achen input
   The load resistance in ohms
into the working mode
reloaded manual ultrasonic inspection
E P8527 / 1
0-1A
-
1A
(300 ± 6) Ohm
E P8527 / 2
0-5A
-
5A
(300 ± 6) Ohm
E P8527 / 3
0-400V
400-520V
400V
(800 ± 24) ohms
E P8527 / 4
-
0-20A
1A
(300 ± 6) Ohm
E P8527 / 5
-
0-40A
1A
(300 ± 6) Ohm
E P8527 / 6
-
50A-0
1A
(300 ± 6) Ohm
E P8527 / 7
-
100A-0
5A
(300 ± 6) Ohm
E P8527 / 8
-
0-125A
5A
(300 ± 6) Ohm
E P8527 / 9
-
200A-0
5A
(300 ± 6) Ohm
E P8527/10
-
250A-0
5A
(300 ± 6) Ohm
E P8527/11
-
300A-0
5A
(300 ± 6) Ohm
E P8527/12
10A-0
-
10A
(300 ± 6) Ohm
E P8527/13
0-100V
100-130V
100B
(800 ± 24) ohms
or
(300 ± 6) Ohm *
E P8527/14
0-1A
1-20A
1A
(70 ± 1,4) Ohm
E P8527/15
0-5A
10A-5
5A
(70 ± 1,4) Ohm
E P8527/16
0-1A
-
1A
(300 ± 6) Ohm
E P8527/17
0-5A
-
5A
(300 ± 6) Ohm
E P8527/18
0-1A
1-20A
1A
(300 ± 6) Ohm
E P8527/19
0-5A
100A-5
5A
(300 ± 6) Ohm
* The value of the load resistance on request.

    Table 2-2. Har akteristiki input and output signals, the resistance of the load.
Modif pecifications device
Normalized RATE value of the input signal
The range of change of the output signal, mA
in TT
overload
in TT
overload
E P8527 / 1
1A
-
0-5.0 mA
-
E P8527 / 2
5A
-
0-5.0 mA
-
E P8527 / 3
400V
520B
0-5.0 mA
5.0-6.5 mA
E P8527 / 4
-
20A
-
0-5.0 mA
E P8527 / 5
-
40A
-
0-5.0 mA
E P8527 / 6
-
50A
-
0-5.0 mA
E P8527 / 7
-
100A
-
0-5.0 mA
E P8527 / 8
-
125A
-
0-5.0 mA
E P8527 / 9
-
200A
-
0-5.0 mA
E P8527/10
-
250A
-
0-5.0 mA
E P8527/11
-
300A
-
0-5.0 mA
E P8527/12
10A
-
0-5.0 mA
-
E P8527/13
100B
130B
0-5.0 mA
5.0-6.5 mA
E P8527/14
1A
20A
0-5.0 mA
5,0-100mA
E P8527/15
5A
100A
0-5.0 mA
5,0-100mA
E P8527/16
1A
-
0-5.0 mA
-
E P8527/17
5A
-
0-5.0 mA
-
E P8527/18
1A
20A
0-5.0 mA
5,0-100mA
E P8527/19
5A
100A
0-5.0 mA
5,0-100mA
* The value of the load resistance on request.
   
The value of the WMO -stand resistance transducer EP8527 when the input signal is equal to the final value of the measuring range of the working mode is:
    - For type 3 - at least 55kOm;
    - For type 13 - at least 9kOm;
    - For types 14, 16-18 - less than 0.2 ohm;
    - For types 15, 19 - not more than 0.01 ohms.

    As for types 1, 2, 4-12, due to the lack of input circuits, the installation of which is performed at potrebitelyai depends on the cable cross-section passing through a hole in the unit as a primary winding, the input impedance of the transducer is not standardized.
    Time mja operating mode setting device not more than 5 minutes.
    Time mja continuous operation type converters 1, 2, 4-12, 14-19 is not limited at nominal values ​​of the input signal shown in Table 2, with respect to types 3, 13, uptime is not limited by the maximum values ​​of the input signal reloading modes in the table. Continuous operation type converters 4-11, 14, 15, 18, ​​19, with maximum values ​​of the input signal reloading conditions shown in Table 2, no more than 5 minutes to 2 hours repetition.
    Number overloads to 60A input current without damage to equipment types 1, 16, 17 - two, and two types of devices, 12 - to 300 1 sec intervals between overloads 4:00.
    Apparatus Types 3, 13 is maintained without damaging overloads nine input voltage equal to 150% of the nominal value, duration 0.5 s intervals between 15 overloads. The output signal in case of overload does not exceed the maximum load on the 15V - AC voltage (rms).
    In Table 3, the values ​​allowed filed additional reduced errors caused by changes in the influencing factors of the normal range
    a) to -30 ° C and +50 ° sleep every 10 ° C with ambient temperature changes from (20 ± 2) ° C for three types of transmitters 13, 14, 15 and (20 ± 5) ° C for type 1, 2, 4-12, 16-19:
    - Pr Edelev main types of error for the EP8527 3, 13, 14, 15 TT span input and 0.8 limits the basic error in reloading mode input range of measurements;
    - Basic error limits of 0.5 to 1, 2, 4-12, 16-19;
    b) under the influence of relative humidity (95 ± 3)% at 35 ° C:
    - Twice the basic error limits for types 3, 13, 14, 15 TT span input and 1,8 outside the basic error range in the shifting mode, the measurement input signal;
    - Basic error limits for types 1, 2, 4-12, 16-19;
    c) under the influence of an external uniform magnetic field of an AC frequency of the measured signal tokas 45-55Hz with a magnetic induction of 0.5 mT at the most unfavorable direction and phase of the magnetic field:
    - Twice the basic error limits for 3, 13, 14, 15 in the operating mode of the measuring range of input signal and the limits of the basic error in reloading mode, the measurement range of input signal;
    - Basic error limits of 0.5 to 1, 2, 4-12, 16-19.

    Table 3. Normal values ​​affect the values ​​of permissible error values.
S factor affecting
Normal value noe
Eratura Ambient Temp, ° C:
 
- For EP8527 / 3, 13, 14, 15
20 ± 2 ° C
- For1 2, 4 - 12, 16-19
20 ± 5 ° C
Of relative humidity of the ambient air,%
30 -80%
Ernoe atmosphere pressure, kPa (mm rt.s.)
84kPa - 106.7 kPa (630-800) mmrt.s.
Four ma curve AC (alternating voltage) of the input signal,%
Xing usoidalnaya a factor of higher harmonics are not more than 2%
Input Frequency, Hz
50 ± 1 Hz
With loads Resistivity, Ohm:
 
-Types EP8527 / 1, 2, 4-12
EP85 27/16-EP8527/19
(3, 00 ± 6) Ohm
- Type 3
(8, 00 ± 24) ohms
- Types 13
(8, 00 ± 24) ohms or (300 ± 6) Ohm
- Types 14, 15
(70 ± 1,4) Ohm
Mag netic and electric fields
Cal practice the absence of magnetic and electric fields, except for the earth
Ra bochee position SP
Any
   
When the input signal is equal to the final value of the measuring range of the working mode converter consumes otizmeritelnoy circuit capacity is not more than:
    - For types 14 -19 - 1.0 V · A;
    - For Type 3 - 3.0 V · A;
    - For type 13 - 1.5 V · A.
    D converter Overall dimensions up to:
    - 50h75h130 mm (for types 1, 2, 4-12);
    - 110h120h125 mm (for types 3, 13);
    - 110h120h70 mm (for types 14-19).
    Ma cca all types of transducers are not more than 1.5 kg.

    For drives EP8527 all types with re dnyaya MTBF with uchetomtehnicheskogo service of at least 50,000 hours. Mean time to repair a healthy state, not more 2:00. The average service life of at least 10 years.  

Photos ЭП8527

EP8527 device image.
EP8527 device image.
EP8527/1, 2, 12 EP8527/4-11 connection scheme.
EP8527/1, 2, 12 EP8527/4-11 connection scheme.
EP8527 / 1, 2, 4-12 scheme electrical connections.
EP8527 / 1, 2, 4-12 scheme electrical connections.
EP8527/1, 2, 4-12 overall dimensions.
EP8527/1, 2, 4-12 overall dimensions.
EP8527/1, 2, 4-12 installation dimensions.
EP8527/1, 2, 4-12 installation dimensions.
EP8527/3, 13 overall dimensions.
EP8527/3, 13 overall dimensions.
EP8527/14-19 overall dimensions.
EP8527/14-19 overall dimensions.
EP8527/3, 13-19 installation dimensions.
EP8527/3, 13-19 installation dimensions.
EP8527/3, 13-19 scheme electrical connections.
EP8527/3, 13-19 scheme electrical connections.