Electrical measuring instruments >> analog panel meters >> ammeters and voltmeters >> DC >> size 60x60mm

EA2231

4 425 RUB
2 478 UAH
available:
124 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.
Ammeter EA2231, EA2231 milliammeter, kiloampermetr EA2231 (EA 2231, EA-2231)
 
Ammeter EA2231, EA2231 milliammeter, kiloampermetr EA2231 used to measure the strength of DC electric circuits of stationary and portable devices.
Dimensions - 60h60h50mm.
Class of accuracy - 1.5-2.5.
 
Technical characteristics of the devices ammeters EA2231, EA2231 milliammeter, kiloampermetry EA2231:
 
Designed for integration into the measuring and test equipment, are used to measure the strength of DC electric circuits of fixed and portable devices operating in the unheated rooms closed.
Micro, Milli-, kilo-, ammeters EA2231 - Equipment magneto system with fastening the movable part in the cores and thrust.
Working position of the device ammeter EA2231, EA2231 milliammeter, kiloampermetr EA2231 - horizontal and vertical.
 
Characteristics of the devices milliammeter EA2231 EA2231 and ammeter:
 
- measurement range
Accuracy class
Ohm internal resistance, no more
Voltage drop, max, mV
0 mA-1mA
2.5
150 ohms
 
1mA 1mA, 0 mA-
1.5
75 Ohm
 
0 mA-5mA
2.5
15 Ohm
 
5mA 5mA, 0 mA-
1.5
7.5 Ohm
 
0 mA-10 mA
2.5
7.5 Ohm
 
10mA-10mA-0 mA
1.5
7.5 Ohm
 
0 mA-30 mA
2.5
2 ohms
 
30mA-30mA-0 mA
1.5
2 ohms
 
0 mA-50mA
2.5
 
90mV
50mA-50mA-0 mA
1.5
 
0 mA-100 mA
2.5
 
100mA-100mA-0 mA
1.5
 
0 mA-150 mA
2.5
 
150mA-150mA-0 mA
1.5
 
0 mA-300 mA
2.5
 
30mA, 0 mA-300 mA
1.5
 
0 mA-500mA
2.5
 
500mA-500mA-0 mA
1.5
 
0A-1A
2.5
 
1A-0A-1A
1.5
 
0A-3A
2.5
 
3A-0A-3A
1.5
 
0A-5A
2.5
 
5A-0A-5A
1.5
 
0A-10A
2.5
 
10A-0A-10A
1.5
 
 
Characteristics of the devices and ammeter EA2231 EA2231 kiloampermetr with some auxiliary parts:
 
- measurement range
Accuracy class
Way to incorporate
Voltage drop, max, mV
0A-20A
2.5
With a measuring shunt loop 75 M3
on the wires 20A and KP1-4
75mV
20A-0A-20A
1.5
0A-30A
2.5
With a measuring shunt loop 75 M3
on the wires 30A and KP1-4
30A-0A-30A
1.5
0A-50A
2.5
With a measuring shunt loop 75 M3
on the wires 50A and KP1-4
50A-0A-50A
1.5
0A-75A
2.5
With a measuring shunt loop 75 M3
at 75A and wires KP1-4 / 5
75A-0A-75A
1.5
0A-100A
2.5
With a measuring shunt loop 75 M3
on the wires 100A and KP1-4 / 5
100A-100A-0s
1.5
0A-150A
2.5
With a measuring shunt loop 75 M3
to 150A and wire KP1-4 / 5
150A-150A-0s
1.5
0A-200A
2.5
With a measuring shunt loop 75 M3
to 200A and wire KP1-4 / 5
200A-200A-0s
1.5
0A-300A
2.5
With a measuring shunt loop 75 M3
to 300A and wire KP1-4 / 5
300A-300A-0s
1.5
0A-500A
2.5
With a measuring shunt loop 75 M3
to 500A and wire KP1-4 / 5
500A-500A-0s
1.5
0A-750A
2.5
With a measuring shunt loop 75 M3
to 750A and wire KP1-4 / 5
750A-750A-0s
1.5
200A-750A-0s
1.5
0kA-1kA
2.5
With a measuring shunt loop 75 M3
at 1000A and wires KP1-4 / 5
1kA-0kA-1kA
1.5
0kA-1, 5kA
2.5
With a measuring shunt loop 75 M3
at 1500A and wires KP1-4 / 5
1.5 kA-0kA-1, 5kA
1.5
0kA-4kA
2.5
With a measuring shunt loop 75 M3
at 4000A and wires KP1-4 / 5
4kA-0kA-4kA
1.5
0kA-6kA
2.5
With a measuring shunt loop 75 M3
at 6000A and wires KP1-4 / 5
6kA-0kA-6kA
1.5
0kA-7 5kA
2.5
With a measuring shunt loop 75 M3
at 7500A and wires KP1-4 / 5
7.5 kA-0kA-7 5kA
1.5
 
Characteristics of the devices and ammeter EA2231 EA2231 amperkilovoltmetr with separate auxiliary units
 
- measurement range
Current
Measuring ranges for voltage
The current total deviation
Voltage drop
Accuracy class
Way to incorporate
0A-1A
0kV-3kV
5.0 mA
75mV
2.5
On an individual and an additional shunt resistor P105
DS 0.6 megohms; 5mA
(Type R103)
 
Ambient air temperature - from -50 º C to +60 ° C.
Relative humidity - 95% at 35 ° C.
Unit weight ammeter EA2231, EA2231 milliammeter, kiloampermetr EA2231 - 0.15 kg.
Dimensions - 60h60h50mm.
In agreement with the client devices ammeter EA2231, EA2231 milliammeter, kiloampermetr EA2231 can be manufactured with special scales and unfilled sealant.
Example entries in order and in the technical documentation of other products:
- "Milliammeter EA2231, 0-1 mA, TU 4223-001-05798310-99";
- Unfilled sealant:
- "Milliammeter EA2231A, 0-1 mA, TU 4223-001-05798310-99;
- Special Scale:
- "Milliammeter EA2231.X, TU 4223-001-05798310-99 ", where X - the performance of the design documentation;
An example entry device with measuring ranges EA2231 0A-1A and 0.3 kV without additional resistance R103:
- "Amperkilovoltmetr EA2231, 0.1 Au 0.3 kV, without R103, TU4223-001-05798310-99."
 

Photos EA2231

EA2231 front view (scale).
EA2231 front view (scale).
EA2231 side view (casing depth).
EA2231 side view (casing depth).
EA2231 rear view (connection).
EA2231 rear view (connection).


Яндекс цитирования