Electrical measuring instruments >> analog panel meters >> ammeters and voltmeters >> alternating current low-frequency (less 1000Hz) >> size 120x120mm

E325

999 RUB
250 UAH
available:
51 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.

    Voltmeter E325 (E 325, E-325, E325, E 325, E-325; Є325; Є 325; Є 325, E325, E 325, E-325)

    Voltmeter E325 - panel meter electromagnetic system is designed to measure current and voltage in alternating current frequency of 50 Hz - 1000 Hz.

    Accuracy class - 1.5.
    Front dimensions - 120 × 120 mm.
    In Voltmeter E325 used in the state metrological control and supervision.

    Specifications E325

    Voltmeters E325 allow basic measurement error does not exceed ± 1,5% of full scale value.
    Changing E325 readings due to abnormal ambient temperature of 20 ° C (in the range of -40 º C to +50 ° C) does not exceed ± 0,8% - for Class 1.5 for every 10 degrees.

    Terms of use E325

    Voltmeter E325 suitable for use at temperatures between -50 º C and +60 º C. Relative humidity should be no more than 95% (at +35 º C).
    E325 devices made ​​in the body splash proof.

    Positioning and mounting E325

    Ammeters and voltmeters E325 E325 designed for flush mounting on vertical or horizontal panels (panels) made ​​as of the magnetic and non-magnetic materials.

    When installing the E325 need to adhere to the following rules:
    - Installation of equipment should be made ​​carefully, without distortions;
    - Fastening voltmeters E325 panel must be rigid and not create additional stress;
    - VoltmetrE325 the installation should be located away from sources of strong magnetic fields with a strength greater than 0.4 kA / m;
    - Appliances intended for inclusion in the network with a voltage of more than 650V, mounted on insulators of reach to touch.

    The manufacturer guarantees that the device specification requirements under normal use, storage, transportation and installation.
    Voltmeter E325 meets the requirements for ensuring safety of life, health, consumer and environmental protection.

Photos: E325

E325 device image.
E325 device image.
E325 front view (scale).
E325 front view (scale).
E325 side view (casing depth).
E325 side view (casing depth).
E325 rear view (connection).
E325 rear view (connection).