    Coaxial transition E2-32 (SR-50-242)
    Also, this device can be called: E232, E2 32, SR50242, SR 50 242, cp-50-242, cp50242, cp 50 242.

    Coaxial transition E2-32 (SR-50-242) is designed for measuring coaxial connection paths that end with the connectors connecting the series 7B-7B, the measurements of various kinds.
    Adapter coaxial measurement should conform to the general specifications in terms of requirements and standards.
   
   
Technical specifications of the devices coaxial transitions E2-32 (SR-50-242)
    Characteristic impedance - 50 ohms.
    Channel Types - VI - IV.
    The maximum operating frequency of transitions E2-32 (SR-50-242) - up to 10 GHz.
    Operating frequency range transitions - 2.5-10 GHz.
    The electrical length of transitions (joint) - 52 mm.
    Voltage standing wave ratio (VSWR) of the transitions at frequencies up to 10 GHz - 1.15.
    The efforts of the dismemberment of contact-pin socket - 0.5-2.0 kg · s.

    Test voltage transitions at the frequency of 50 Hz:
    - Under normal conditions - 1000;
    - At 98% humidity and a temperature of +40 ° C - 700 V.

    Insulation resistance E2-32 (SR-50-242)
    - Normal - 1000 MW;
    - At 98% humidity and a temperature of +40 ° C - 50 MW;
    - At a temperature of +70 ° C - 50 Mohm.
   
    Spanner:
    - Screws - 22 mm;
    - Bushes - 17 mm.
    Weight E2-32 (SR-50-242) - not more than '60
    Operating Environment E2-32 (SR-50-242)
    Atmospheric pressure - 720-780 mm Hg
    Maximum operating voltage under normal conditions at a humidity of 98% (at a temperature of +40 ° C) - 300 V.
   
    Vibration resistance:
    - Frequency range - 5-200 Hz;
    - Acceleration - 7.5 m / s 2.
    Multiple-shock, acceleration - 35 m / s 2.
    Thermal stability: +70 ° C.
    Resistance to cold: -50 ° C.
    Temperature cycling, the number of cycles - 3.
    The highest relative humidity at +40 ° C - 98%.

    Shelf life transitions coaxial E2-32 (SR-50-242)
    - In terms of storage - 8 years;
    - Including in the field - 3 years.

Photos: E2-32 (SR-50-242, CP-50-242)

E2-32 (SR-50-242) transition image.
E2-32 (SR-50-242) transition image.
E2-32 (SR-50-242) transition image.
E2-32 (SR-50-242) transition image.
E2-32 (SR-50-242) front view.
E2-32 (SR-50-242) front view.
E2-32 (SR-50-242) side view.
E2-32 (SR-50-242) side view.
E2-32 (SR-50-242) rear view.
E2-32 (SR-50-242) rear view.


Яндекс цитирования