    Coaxial transition E2-30 (SR-50-240)
    Also, this device can be called: E230, E2 30, SR50240, SR 50 240, cp-50-240, cp50240, cp 50 240.
    Coaxial transition E2-30 (SR-50-240) is designed for measuring coaxial connection paths that end with the connectors connecting the series 7B-7B, the measurements of various kinds.
    Adapter coaxial measurement should conform to the general specifications in terms of requirements and standards.
    Technical specifications of the devices coaxial transitions E2-30 (SR-50-240)
    Characteristic impedance - 50 ohms.
    Channel Types - VI - IV.
    The maximum operating frequency of transitions E2-30 (CP-50-240) - up to 10 GHz.
    Operating frequency range transitions - 2.5-10 GHz.
    Voltage standing wave ratio (VSWR) of the transitions at frequencies up to 10 GHz - 1.05.
    The efforts of the dismemberment of contact-pin socket - 0.5-2.0 kg · s.
    Test voltage transitions at the frequency of 50 Hz:
    - Under normal conditions - 1000;
    - At 98% humidity and a temperature of +40 ° C - 700 V.
    Insulation resistance E2-30 (SR-50-240)
    - Normal - 1000 MW;
    - At 98% humidity and a temperature of +40 ° C - 50 MW;
    - At a temperature of +70 ° C - 50 Mohm.
    The size of the chassis, under the - 22 mm.
    Weight E2-30 (SR-50-240) - no more than '60
    Operating Environment E2-30 (SR-50-240)
    Atmospheric pressure - 720-780 mm Hg
    Maximum operating voltage under normal conditions at a humidity of 98% (at a temperature of +40 ° C) - 300 V.
    Vibration resistance:
    - Frequency range - 5-200 Hz;
    - Acceleration - 7.5 m / s 2.
    Multiple-shock, acceleration - 35 m / s 2.
    Thermal stability: +70 ° C.
    Resistance to cold: -50 ° C.
    Temperature cycling, the number of cycles - 3.
    The highest relative humidity at +40 ° C - 98%.
    Shelf life transitions coaxial E2-30 (SR-50-240)
    - In terms of storage - 8 years;
    - Including in the field - 3 years.

Photos: E2-30 (SR-50-240, CP-50-240)

E2-30 (SR-50-240, CP-50-240) transition image.
E2-30 (SR-50-240, CP-50-240) transition image.
E2-30 (SR-50-240, CP-50-240) front view.
E2-30 (SR-50-240, CP-50-240) front view.
E2-30 (SR-50-240, CP-50-240) side view №1.
E2-30 (SR-50-240, CP-50-240) side view №1.
E2-30 (SR-50-240, CP-50-240) side view №2.
E2-30 (SR-50-240, CP-50-240) side view №2.
E2-30 (SR-50-240, CP-50-240) side view №3.
E2-30 (SR-50-240, CP-50-240) side view №3.


Яндекс цитирования