Transformer DSPU-128 KF3.010.034 rotating multi odnootschetny open-frame (DSPU128, DSPU 128)
 
Rotary transformers DSPU-128 is a two-pole contact four stretch wrapping machines.
Depending on the scheme and the inclusion mode (function) devices transformer rotating multi odnootschetny open-frame DSPU-128 divided by sine-cosine (Synchro), output voltage which is proportional to the sine (cosine) the angle of rotation of the rotor, and linear (LVT), the output voltage which varies linearly proportional to the angle of ± 60 °.
 
Technical characteristics of the instrument transformers DSPU-128 KF3.010.034 rotating multi-pole frameless odnootschetnye:
 
Operation - Synchro, VTDP-D;
The current instrument transformer DSPU-128 rotating multi odnootschetny open-frame - 190mA;
Nominal voltage - 12V;
Maximum output voltage - 0.025;
Residual EDS instrument transformer DSPU-128 open-frame rotating multi odnootschetny - 0.09 mV;
Nominal frequency of the excitation voltage - 400 Hz;
Operating frequency range of excitation voltage - 380Gts-4200Gts;
Change the position of agreement with the ambient temperature changes - 128ugl.s;
The steepness of the instrument transformer DSPU-128 open-frame rotating multi odnootschetny - 0.75 mV / ang;
The ratio of residual to the steepness of the EMF - 0.12 ang;
Phase shift of the output EMF - 88ugl.grad;
Rotary transformers DSPU-128 are divided into accuracy classes:
- Transformer DSPU-128 Class 1 accuracy (1st class. T) has the characteristics:
- Accuracy of repetition TPD composed of DSPU-128 - ± 0,15 ang;
- Transformer DSPU-128 Class 2 accuracy (2 cl. T) has the characteristics:
- Accuracy of repetition TPD composed of DSPU-128 - ± 0,2 ang;
- Transformer DSPU-128 Class 3 accuracy (3 cl. T) has the characteristics:
- Accuracy of repetition TPD composed of DSPU-128 - ± 0,3 ang;
- Transformer DSPU-128 4 class accuracy (4 cl. T) has the characteristics:
- Accuracy of repetition TPD composed of DSPU-128 - ± 0,3 ang;
- Transformer DSPU-128 Class 5 precision (5 cl. T) has the characteristics:
- Accuracy of repetition TPD composed of DSPU-128 - ± 0,3 ang;
Dimensions instrument transformer rotating DSPU-128 multi-odnootschetny open-frame:
- Diameter - 100 mm;
- Length - 10mm;
Unit weight transformer DSPU-128 rotating multi odnootschetny open-frame - 0.3 kg;
Vibration loads:
- Frequency range - up to 3000Gts;
- Acceleration - 200m / s 2;
Shock - 750m / s 2;
Ambient temperature - -60 ° C to +100 º C;
Relative humidity at 35 ° C - 98%;
Warranty life instrument DSPU-128 transformer rotating multi odnootschetny open-frame - 10,000 hours;
The manufacturer guarantees the quality of the instrument transformer DSPU-128 rotating multi odnootschetny open-frame the technical requirements specifications subject to user terms and conditions of storage, transportation, installation, operation and technical specifications established by the operational documentation.

Photos DSPU-128 KF3.010.034

DSPU-128 KF3.010.034 device image.
DSPU-128 KF3.010.034 device image.
DSPU-128 KF3.010.034 accessories and spare parts.
DSPU-128 KF3.010.034 accessories and spare parts.
DSPU-128 KF3.010.034 front view.
DSPU-128 KF3.010.034 front view.
DSPU-128 KF3.010.034 side view.
DSPU-128 KF3.010.034 side view.


Яндекс цитирования