Laboratory equipment >> dosimeters, radiometers

DRG-T Radiation detection device DRG-T.

DRG-T

23 999 RUB
8 400 UAH
available:
1 piece

Online prices include VAT.

For order is possible effectively delivery of any quantity.
Radiation survey instrument DRG-T (DRGT, DRG T)
 
Radiation survey instrument DRG-T is designed for use in special vehicles for the purpose of continuous monitoring and measurement of exposure dose rate (EDR) of gamma-and X-rays, as well as to provide audible and visual alarm about the dangerous levels of radiation and give commands to the inclusion actuators remedies.
Application of the device radiation survey instrument DRG-T:
The device is intended for use in special-purpose vehicles, particularly in the departments of radiochemical intelligence Civil Defense and the armed forces.
Special features of radiation reconnaissance unit DRG-T:
- High shock and vibration resistance device;
- Ability to accommodate different degrees of attenuation of gamma radiation;
- Issuance of signals for display on the bulletin boards of the vehicle;
- Issuing instructions to discharge the executive mechanisms to protect the vehicle crew;
- Built-in monitoring the functioning of the device with the issue without issuing commands to the actuators;
- Ability to output of data to the onboard computer.
 
Technical characteristics of the devices radiation survey instruments DRG-T:
 
The range of measurements of gamma radiation EDR - from 1.10 -5 F / hour to 1000R/chas;
Range of detected gamma radiation survey instrument instrument DRG-T - 0.66 MeV to 1.25 MeV;
Maximum permissible relative basic error in the measurement of gamma radiation EDR (for 137Cs) with a confidence level of 0.95:
 
δH = (15 +0.2 / X)%
 
where X - a numeric value of the measured dose rate, equivalent to millirentgenam per hour;
Energy dependence of the device shows the device radiation survey DRG-T in the measurement of gamma radiation is ± 25% in the range from 0.66 MeV to 1.25 MeV;
The device generates commands and signals in the presence of (at least 3 s) at the location of the unit of gamma radiation with energies of gamma-ray 0.66 MeV, dose rate exceeds a threshold level of "P" (EDR more than 50mR/chas);
The unit radiation survey instrument DRG-T generates commands and signals in the presence of (at least 0.1 s) at the location of the unit of gamma radiation with energies of gamma-ray 1.25 MeV, dose rate exceeds a threshold level "A" (DER more than 14400R/chas);
Power supply is carried on-board DC power supply from 9.0 to 28.5 V;
Current consumption of the unit radiation survey instrument DRG-T at a nominal voltage of 24 V is less than 1.0 A;
Continuous operation time - not less than 48 hours, followed by disconnection of at least 2 hours;
Operating temperature range of devices radiation survey instrument DRG-T - from -40 º C to 60 ° C;
Overall dimensions - 160 × 160 × 110mm;
Weight of the device radiation survey instrument DRG-T does not exceed 4 kg;
Enclosure - IP-56;
Mean time to failure - at least 4,000 hours;
Average life instrument radiation survey instrument DRG-T - no less than 20 years with routine maintenance over 10 years;
The average shelf life - at least 15 years;
Delivery set
- The unit of radiation reconnaissance RGD-T;
Instruction Manual
- Form;
Installation elements kit
Packing.
The manufacturer guarantees the quality of the unit radiation survey instrument DRG-T technical requirements specifications, subject to the consumer the terms and conditions of storage, transportation, installation, operation, established specifications and operational documents. 


Яндекс цитирования