Electrical measuring instruments >> phase meters

D5782

69 999 RUB
28 000 UAH
available:
4 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.

Phase meter D5782 (D 5782, D-5782)

D5782 (hereinafter - phase meter) single-phase, electrodynamic system, portable, shielded, designed to determine in single-phase AC 50Hz and 60Hz phase angle between the main harmonic components of current and voltage.

    Accuracy class 0.5.
Rated currents 5A 10A
    Rated voltage 100V, 220V, 380V
Measuring range for the values ​​of the phase angle 0-90-180-270-360 ˚; cosφ values ​​for   1-0-1-0-1.

Phase meter D5782 (hereinafter - phase meter s) single-phase, electrodynamic system, portable, shielded, designed to determine a single-phase alternating current at 50 Hz and 60 of the phase angle between the main harmonic components of current and voltage

D5782 is designed for use in enclosed dry heated rooms in a temperate climate at an ambient temperature of 10 to 35 ° C and a relative humidity of 80% at 30 ° C, Phase meter D5782 - 04.1 - general climatic performance - indoors at a temperature of 1 to 45 ° C and relative humidity of 80% at 25 ° C under dry and humid tropical climates.

SPECIFICATIONS

Accuracy class 0.5 in accordance with GOST 8039-79.

Rated currents and voltages, the normal rate shown in Table. 1.

Table 1.

 

Phase meter D5782
Designation Symbol Nominal current, A Nominal voltage, V The normal frequency in Hz

PEA. 393.047-01

PEA. 393.047-01.10

D5782 5A 10A 100V, 220V, 380V 60Hz
PEA. 393.047-01.20 D5782-04.1


Maximum permissible error of phase meters D5782, directly after the start and during any time of continuous operation, do not exceed ± 0,5% from 180 ° scales, graduated in the values ​​of the phase angle, and ± 0,5% of the length of the scale, the scale for , calibrated cosφ values ​​in this region changes in the series circuit current of 20 to 100% of nominal value.
Range:

for the values ​​of the phase angle 0-90-180-270-360 ˚;

for the values ​​of cosφ    1-0-1-0-1.


Own consumption of sequential circuits with rated current and normal frequency of less than 5 V · A; own consumption parallel circuit at rated voltage and normal frequency does not exceed 8 V · A. Response time phase meters D5782 does not exceed 4 c. Dimensions phase meters D5782 do not exceed 230x280x140 mm. Weight phase meters shall not exceed 6.5 kg.

Photos: D5782

D5782 phase meter image.
D5782 phase meter image.
D5782 front view.
D5782 front view.
D5782 side view (terminals, switches).
D5782 side view (terminals, switches).
D5782 side view.
D5782 side view.
D5782 side view.
D5782 side view.
D5782 rear view.
D5782 rear view.


Яндекс цитирования