Wattmeter D539 (D-539, D 539)
 
D539 Power Meter is designed to measure active power in AC circuits frequency from 45Hz to 65Hz, as well as in the extended frequency range from 65Hz to 500Hz, inclusive, and in DC.
Wattmeters can also be used for measurement in AC circuits in the frequency range from 500Hz to 1500Hz, inclusive, with the main error of devices normally not exceed ± 2,5% of full scale of the working part of the scale;
A distinctive feature of the device is its own small power consumption.
 
Technical characteristics of the devices wattmeters D539:
 
Accuracy class - 0.5;
Devices wattmeter D539 is available in two versions:
- Type D539 - to work indoors at an ambient temperature of +10 ° C to +35 º C at a relative humidity of 80%;
- Type D539T - (tropical version) - for indoors in a tropical climate;
Wattmeter D539 manufactured by four nominal voltage and two nominal current shown in Table 1, as well as two nominal voltage n two nominal current according to Table 2;
 
Table 1 Characteristics of the device wattmeter D539 four nominal voltage and current of two nominal
Modification of the device Voltage ratings Rated currents
1 2 3 4 5 6 7
D539 / 1 30B 75V 150V 300V 5A 10A
D539 / 2 75V 150V 300V 600V 5A 10A
D539 / 3 30B 75V 150V 300V 2.5 A 5A
D539 / 4 75V 150V 300V 600V 2.5 A 5A
D539 / 5 30B 75V 150V 300V 1A (2a)
D539 / 6 75V 150V 300V 600V 1A (2a)
D539 / 7 30B 75V 150V 300V 0.5 A 1A
D539 / 8 75V 150V 300V 600V 0.5 A 1A
D539 / 9 30B 75V 150V 300V 0.25 A 0.5 A
D539/10 75V 150V 300V 600V 0.25 A 0.5 A
D539/11 30B 75V 150V 300V 0.1 A 0.2 A
D539/12 75V 150V 300V 600V 0.1 A 0.2 A
D539/13 30B 75V 150V 300V 50mA 100mA
D539/14 75V 150V 300V 600V 50mA 100mA
D539/15 30B 75V 150V 300V 25mA 50mA
D539/16 75V 150V 300V 600V 25mA 50mA
D539/17 30B 75V 150V 300V 10mA 20mA
D539/18 75V 150V 300V 600V 10mA 20mA
 
Table 2 Characteristics of the device wattmeter D539 on two nominal voltage and current of two nominal
Modification of the device Voltage ratings Rated currents
1 2 3 4 5
D539/19 100B 300V 5A 10A
D539/20 150V 300V 5A 10A
 
The final values ​​of the working part of the instrument scale wattmeter D539 are shown in Table 3 and Table 4;
 
Table 3: The final values ​​of the working part of the instrument scale wattmeter D539
Modification of the device Rated currents The final values ​​of the working end of the scale at the rated voltage
1 2 3 4 5 6 7
    30B 75V 150V 300V 600V
D539 / 1 5A
10A
150W
300W
375Vt
750W
750W
1500W
1500W
3000W
-
-
D539 / 2 5A
10A
-
-
375Vt
750W
750W
1500W
1500W
3000W
3000W
6000Vt
D539 / 3 2.5 A
5A
75W
150W
187.5 Tues
375Vt
375Vt
750W
750W
1500W
-
-
D539 / 4 2.5 A
5A
-
-
187.5 Tues
375Vt
375Vt
750W
750W
1500W
1500W
3000W
D539 / 5 1A
(2a)
30W
60W
75W
150W
150W
300W
300W
600W
-
-
D539 / 6 1A
(2a)
-
-
75W
150W
150W
300W
300W
600W
600W
1200W
D539 / 7 0.5 A
1A
15W
30W
37.5 W
75W
75W
150W
150W
300W
-
-
D539 / 8 0.5 A
1A
-
-
37.5 W
75W
75W
150W
150W
300W
300W
600W
D539 / 9 0.25 A
0.5 A
7.5 W
15W
37.5 W
75W
75W
150W
150W
300W
-
-
D539/10 0.25 A
0.5 A
-
-
37.5 W
75W
75W
150W
150W
300W
150W
300W
D539/11 0.1 A
0.2 A
3W
6W
7.5 W
15W
15W
30W
30W
60W
-
-
D539/12 0.1 A
0.2 A
-
-
7.5 W
15W
15W
30W
30W
60W
60W
120W
D539/13 50mA
100mA
1.5 W
3W
3.75 W
7.5 W
7.5 W
15W
15W
30W
-
-
D539/14 50mA
100mA
-
-
3.75 W
7.5 W
7.5 W
15W
15W
30W
30W
60W
D539/15 25mA
50mA
0.75 W
1.5 W
1.875 Tues
3.75 W
3.75 W
7.5 W
7.5 W
15W
-
-
D539/16 25mA
50mA
-
-
1.875 Tues
3.75 W
3.75 W
7.5 W
7.5 W
15W
15W
30W
D539/17 10mA
20mA
0.3 W
0.6 W
0.75 W
1.5 W
1.5 W
3W
3W
6W
-
-
D539/18 10mA
20mA
-
-
0.75 W
1.5 W
1.5 W
3W
3W
6W
6W
12W
 
Table 4: The final values ​​of the working part of the instrument scale wattmeter D539
Modification of the device Rated currents The final values ​​of the working end of the scale at the rated voltage
1 2 5 6 7
    100B 150V 300V
D539/19 5A
10A
500W
1000W
-
-
1500W
3000W
D539/20 5A
10A
-
-
750W
1500W
1500W
3000W
 
Key device parameters wattmeter D539 are summarized in Table 5 and Table 6;
 
Table 5: Key device parameters wattmeter D539
Modification of the device Rated currents The resistance of the series circuit (approximately) Inductance series circuit (approximately)
1 2 3 4
D539 / 1 5A
10A
0.006 Ohm
0.003 Ohm
0.005 mH
0.002 mH
D539 / 2 5A
10A
0.006 Ohm
0.003 Ohm
0.005 mH
0.002 mH
D539 / 3 2.5 A
5A
0.008 Ohm
0.004 Ohm
0.02 mH
0.005 mH
D539 / 4 2.5 A
5A
0.008 Ohm
0.004 Ohm
0.02 mH
0.005 mH
D539 / 5 1A
(2a)
0.028 Ohm
0.014 Ohm
0.09 mH
0.02 mH
D539 / 6 1A
(2a)
0.028 Ohm
0.014 Ohm
0.09 mH
0.02 mH
D539 / 7 0.5 A
1A
0.068 Ohm
0.034 Ohm
0.36 mH
0.09 mH
D539 / 8 0.5 A
1A
0.068 Ohm
0.034 Ohm
0.36 mH
0.09 mH
D539 / 9 0.25 A
0.5 A
0.27 Ohm
0.068 Ohm
1.5 mH
0.37 mH
D539/10 0.25 A
0.5 A
0.27 Ohm
0.068 Ohm
1.5 mH
0.37 mH
D539/11 0.1 A
0.2 A
1.5 ohms
0.37 Ohm
9mGn
2mGn
D539/12 0.1 A
0.2 A
1.5 ohms
0.37 Ohm
9mGn
2mGn
D539/13 50mA
100mA
5.6 Ohm
1.4 ohms
36mGn
9mGn
D539/14 50mA
100mA
5.6 Ohm
1.4 ohms
36mGn
9mGn
D539/15 25mA
50mA
22.4 Ohm
5.6 Ohm
150mGn
38mGn
D539/16 25mA
50mA
22.4 Ohm
5.6 Ohm
150mGn
38mGn
D539/17 10mA
20mA
140 Ohm
35 Ohm
900mGn
220mGn
D539/18 10mA
20mA
140 Ohm
35 Ohm
900mGn
220mGn
D539/19 5A
10A
0.0045 Ohm
0.0023 Ohm
0005mGn
0.002 mH
D539/20 5A
10A
0.0045 Ohm
0.0023 Ohm
0005mGn
0.002 mH
 
Table 6 Key device parameters wattmeter D539
No Name The value for the power meter unit D539
1 The resistance of the parallel circuit power meter unit D539 respectively nominal voltage:
30B
75V
100B
150V
300V
600V
 
 
10,000 ohms
25,000 ohms
33,333 ohms
50,000 ohms
100,000 ohms
200,000 ohms
2 Rated current of the branch circuit 3mA
3 The error in the readings of the device in the power meter D539 nominal frequency range from 45Hz to 65Hz not more than 0.5% of the final working of the scale
4 The error in the readings of the instrument wattmeter D539 in the extended frequency range from 65Hz to 500Hz inclusive less than 1% of the final value of the working of the scale
5 Rated power factor 1
6 Weight 1.7 kg
 
The manufacturer guarantees that the quality of the instrument wattmeter D539 technical requirements specifications provided the customer terms and conditions of storage, transportation, installation, operation, and its specified operational documentation.

Photos D539

D539 front view (scale).
D539 front view (scale).
D539 side view (casing depth).
D539 side view (casing depth).
D539 rear view (connection).
D539 rear view (connection).


Яндекс цитирования