Electrical measuring instruments >> ammeters

D5014

16 999 RUB
8 160 UAH
available:
31 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.

Ammeter D5014, milliammeter D5014 (D 5014, D-5014)
Designed to measure DC and AC current.
The final value of the measuring range, depending on the modification of 5A, 10A, 2.5A, 5A, 0.5A, 1A, 100mA, 200mA, 25mA, 50mA 5mA, 10mA
Accuracy class 0.2

Ammeter D5014, milliammeter D5014  designed to measure DC and AC current. Ammeters D5014 are designed for use in moderate climate in enclosed dry heated rooms, at an ambient temperature of 10 ° to 35 ° C and a relative humidity of 80% (at 25 ° C).
Ammeters, milliammeters D5014T4.1 (tropical version) designed for use in both dry and humid tropical climate in closed rooms with air conditioned or partially air-conditioned at the ambient temperature from 1 to 40 ° C and a relative humidity of 80% at 25 ° C (according to GOST 15150-69).

Technical data

Ammeter D5014 corresponds to the accuracy class 0.2 in accordance with GOST 8711-78.
Change D5014 ammeter readings caused by changes in the frequency of the upper limit of the normal region to any value in the working frequency range does not exceed ± 0,2% of the final value of the measuring range.
Change D5014 ammeter readings caused by the influence of a uniform external DC or AC (frequency within the normal range of frequencies, but not more than 1 kHz) of the magnetic field with the magnetic flux density of 0.2 mT does not exceed ± 0,2% of the final value of the measuring range.
Response time less than 4s. Dining lighting circuit unit Ammeter D5014 is made from the AC voltage (220 ± 22) at 50 - 60 Hz via a step-down transformer (supplied), or directly from an AC or DC voltage of 4V.
Overall dimensions Ammeter D5014 205h290h135mm not more, weight - not more than 4.5 kg. Overall dimensions of the transformer housing no more than 65h85h45mm, the mass of the transformer is not more than 0.5 kg.

 

Device Modi-
fication
The final value of the measuring range Active resistance of not more than, Ohm Inductance, no more, mH The normal range of frequencies, Hz Operating frequency range, Hz
Ammeter D5014 / 1 5A 0.1 0.03 45-1000 1000-2000
10A 0.05 0.01
D5014 / 2 2.5 A 0.25 0.1
5A 0.1 0.03
D5014 / 3 0.5 A 1.8 0.8 1000-3000
1A 0.7 0.2
Milli-ammeter D5014 / 4 100 mA 18 3.6 45-1000 1000-3000
200 mA 10 0.9
D5014 / 5 25 mA 65 22 1000-1500
50 mA 27 2.0 45-1500 1500-2500
D5014 / 6 5 mA 2000 750 45-300 300-500
10 mA 550 60 45-500 500-1500

Photos: D5014

D5014 device image.
D5014 device image.
D5014 front view.
D5014 front view.
D5014 side view.
D5014 side view.
D5014 rear view.
D5014 rear view.


Яндекс цитирования