Selsyns, rotary transformers, electric motors >> transformers rotating >> VT-2A

VT-2A LSH3.010.042

6 000 RUB   |   6 000 UAH   |  available: 3 pieces
VT-2A LSH3.010.050 transformer image.
Transformer VT-2A LSH3.010.042 rotating (VT2A, VT 2A, bt-2a, VT2A LSH3.010.042, VT 2A LSH3.010.042, VT-2A LSHZ.010.033, bt2a, bt 2a)
Is a two-pole contact chetyrehobmotochnuyu car.
Operation - Synchro;
Rated voltage - 110V;
Input impedance idling - 1000 ohms ± 150 ohms;
Operating frequency range of excitation voltage - 380Gts-510Gts;
Turns Ratio - 0,950 ± 0,019.

More info ...

VT-2A LSH3.010.045

3 000 RUB   |   3 000 UAH   |  available: 8 pieces
VT-2A LSH3.010.050 transformer image.
Transformer VT-2A LSH3.010.045 rotating (VT2A, VT 2A, bt-2a, VT2A LSH3.010.045, VT 2A LSH3.010.045, VT-2A LSHZ.010.045, bt2a, bt 2a)
Is a two-pole contact chetyrehobmotochnuyu car.
Operation - LVT;
Rated voltage - 110V;
Input impedance idling - 950 ohms;
Operating frequency range of excitation voltage - 380Gts-510Gts;
Turns Ratio - 0.565.

More info ...

VT-2A LSH3.010.046

3 000 RUB   |   3 000 UAH   |  available: 10 pieces
VT-2A LSH3.010.050 transformer image.
Transformer VT-2A LSH3.010.046 rotating (VT2A, VT 2A, bt-2a, VT2A LSH3.010.046, VT 2A LSH3.010.046, VT-2A LSHZ.010.046, bt2a, bt 2a)
Is a two-pole contact chetyrehobmotochnuyu car.
Operation - Synchro;
Rated voltage - 110V;
Input impedance idling - 1000 ohms;
Operating frequency range of excitation voltage - 380Gts-510Gts;
Turns Ratio - 0.565.

More info ...

VT-2A LSH3.010.047

3 000 RUB   |   3 000 UAH   |  available: 2 pieces
VT-2A LSH3.010.050 transformer image.
Transformer VT-2A LSH3.010.047 rotating (VT2A, VT 2A, bt-2a, VT2A LSH3.010.047, VT 2A LSH3.010.047, VT-2A LSHZ.010.047, bt2a, bt 2a)
Is a two-pole contact chetyrehobmotochnuyu car.
Operation - Synchro;
Rated voltage - 110V;
Input impedance-load - 4,100 ft;
Operating frequency range of excitation voltage - 380Gts-510Gts;
Turns Ratio - 0.54.

More info ...

VT-2A LSH3.010.048

3 000 RUB   |   3 000 UAH   |  available: 3 pieces
VT-2A LSH3.010.048 transformer image.
Transformer VT-2A LSH3.010.048 rotating (VT2A, VT 2A, bt-2a, VT2A LSH3.010.048, VT 2A LSH3.010.048, VT-2A LSHZ.010.048, bt2a, bt 2a)
Is a two-pole contact chetyrehobmotochnuyu car.
Operation - Synchro;
Rated voltage - 110V;
Input impedance-load - 4,100 ft;
Operating frequency range of excitation voltage - 380Gts-510Gts;
Turns Ratio - 0.96.

More info ...

VT-2A LSH3.010.049

3 000 RUB   |   3 000 UAH   |  available: 5 pieces
VT-2A LSH3.010.050 transformer image.
Transformer VT-2A LSHZ3.010.049 rotating (VT2A, VT 2A, bt-2a, VT2A LSH3.010.049, VT 2A LSH3.010.049, VT-2A LSHZ.010.049, bt2a, bt 2a)
Is a two-pole contact chetyrehobmotochnuyu car.
Operation - Synchro;
Rated voltage - 110V;
Input impedance-load - 480 ohms;
Operating frequency range of excitation voltage - 380Gts-510Gts;
Turns Ratio - 0.565.

More info ...

VT-2A LSH3.010.050

3 000 RUB   |   3 000 UAH   |  available: 2 pieces
VT-2A LSH3.010.050 transformer image.
Transformer VT-2A LSH3.010.050 rotating (VT2A, VT 2A, bt-2a, VT2A LSH3.010.050, VT 2A LSH3.010.050, VT-2A LSHZ.010.050, bt2a, bt 2a)
Is a two-pole contact chetyrehobmotochnuyu car.
Operation - LVT;
Rated voltage - 110V;
Input impedance-load - 440 ohms;
Operating frequency range of excitation voltage - 380Gts-510Gts;
Turns Ratio - 0.565.

More info ...

VT-2A LSH3.010.051

3 000 RUB   |   3 000 UAH   |  available: 9 pieces
VT-2A LSH3.010.050 transformer image.
Transformer VT-2A LSH3.010.051 rotating (VT2A, VT 2A, bt-2a, VT2A LSH3.010.051, VT 2A LSH3.010.051, VT-2A LSHZ.010.051, bt2a, bt 2a)
Is a two-pole contact chetyrehobmotochnuyu car.
Operation - Synchro;
Rated voltage - 110V;
Input impedance idling - 1000 ohms;
Operating frequency range of excitation voltage - 380Gts-510Gts;
Turns Ratio - 0.95.

More info ...

VT-2A LSH3.010.054

3 000 RUB   |   3 000 UAH   |  available: 6 pieces
VT-2A LSH3.010.050 transformer image.
Transformer VT-2A LSH3.010.054 rotating (VT2A, VT 2A, bt-2a, VT2A LSH3.010.054, VT 2A LSH3.010.054, VT-2A LSHZ.010.054, bt2a, bt 2a)
Is a two-pole contact chetyrehobmotochnuyu car.
Operation - MW;
Rated voltage - 110V;
Input impedance idling - 950 ohms;
Operating frequency range of excitation voltage - 380Gts-510Gts;
Turns Ratio - 0.59.

More info ...

VT-2A LSH3.010.055

3 000 RUB   |   3 000 UAH   |  available: 2 pieces
VT-2A LSH3.010.050 transformer image.
Transformer VT-2A LSH3.010.055 rotating (VT2A, VT 2A, bt-2a, VT2A LSH3.010.055, VT 2A LSH3.010.055, VT-2A LSHZ.010.055, bt2a, bt 2a)
Is a two-pole contact chetyrehobmotochnuyu car.
Operation - MW;
Rated voltage - 110V;
Input impedance idling - 1000 ohms;
Operating frequency range of excitation voltage - 380Gts-510Gts;
Turns Ratio - 0.59.

More info ...
Pages: 1 2 3    View all
VT-2AVT-2A LSH3.010.033VT-2A LSH3.010.034
VT-2A LSH3.010.035VT-2A LSH3.010.036VT-2A LSH3.010.037
VT-2A LSH3.010.038VT-2A LSH3.010.039VT-2A LSH3.010.040
VT-2A LSH3.010.041VT-2A LSH3.010.042VT-2A LSH3.010.045
VT-2A LSH3.010.046VT-2A LSH3.010.047VT-2A LSH3.010.048
VT-2A LSH3.010.049VT-2A LSH3.010.050VT-2A LSH3.010.051
VT-2A LSH3.010.054VT-2A LSH3.010.055VT-2A LSH3.010.056
VT-2A LSH3.010.057VT-2A LSH3.010.058VT-2A LSH3.010.059
VT-2A LSH3.010.060VT-2A LSH3.010.061VT-2A LSH3.010.063


Яндекс цитирования