R5054/1 (p5054/1)

19 999 RUB   |   9 600 UAH   |  available: 1 piece
Most conductivity R5054 / 1.
Conductivity bridge R5054/1 (R50541, R 5054 1, R-5054-1, p5054/1, R5054-1, R5054 1, p50541, p 5054 1, p-5054-1, p5054-1, p5054 1)
Designed forload calibration of voltage transformers with them on a zero-differential unit in AC circuits of frequency 50Hz or 60Hz;
Acceptable basic error limit of active and reactive power components of the conductivity or - 4%;
Rated voltage - 100V;
Voltage measurement range - 80% -120% of nominal voltage;
Rated power factor - 0.8;
The nominal value of the total power levels - 1.25 ∙ A ∙ B 1.67 A, 2.5 V ∙ A ∙ A 5V, 10V ∙ A ∙ A 15V, 25V ∙ A.

More info ...

R5054/2

19 999 RUB   |   9 600 UAH   |  available: 8 pieces
Most conductivity R5054 / 2.

    Box conductivity R5054/2 (R 5054/2, R-5054/2, R 5054 2, R-5054-2, R5054-2, R5054 2; r5054 / 2; r 5054/2; r-5054/2; r 5054 2; r-5054-2; r5054-2; r5054 2)
    Box conductivity R5054/2 - a device for use in alternating current frequency of 50 Hz as the load voltage transformers.
    The main limiting errors - 4%.
    Power - AC 220V, 50Hz.


More info ...

R5054/3 (p5054/3)

19 999 RUB   |   9 600 UAH   |  available: 1 piece
R5054/3 (p5054/3) device image.
Conductivity bridge R5054/3 (R50543, R 5054 3, R-5054-3, p5054/3, R5054-3, R5054 3, p50543, p 5054 3, p-5054-3, p5054-3)
Designed forload calibration of voltage transformers with them on a zero-differential unit in AC circuits of frequency 50Hz or 60Hz;
Acceptable basic error limit of active and reactive power components of the conductivity or - 4%;
Rated voltage - 150V;
Voltage measurement range - 20% -120% of nominal voltage;
Rated power factor - 0,8, 1;
The nominal value of the total power levels - 1.25 ∙ A ∙ A 2.5 V, 5 V ∙ A ∙ A 10V, 15V ∙ A.

More info ...

R5054/4 (p5054/4)

19 999 RUB   |   9 600 UAH   |  available: 1 piece
Most conductivity R5054 / 4.
Conductivity bridge R5054/4 (R50544, R 5054 4, R-5054-4, p5054/4, R5054-4, R5054 4, p50544, p 5054 4, p-5054-4, p5054-4, p5054 4)
Designed forload calibration of voltage transformers with them on a zero-differential unit in AC circuits of frequency 50Hz or 60Hz;
Acceptable basic error limit of active and reactive power components of the conductivity or - 4%;
Rated voltage - 100V;
Voltage measurement range - 80% -120% of nominal voltage;
Rated power factor - 1;
The nominal value of the total power levels - 1.25 ∙ A ∙ A 2.5 V, 5 V ∙ A ∙ A 10V, 15V ∙ A.

More info ...

R5054/5 (p5054/5)

19 999 RUB   |   9 600 UAH   |  available: 1 piece
Most conductivity R5054 / 5.
Conductivity bridge R5054/5 (R50545, R 5054 5, R-5054-5, R5054/5, R5054-5, R5054 5, p50545, p 5054 5, p-5054-5, p5054-5, p5054 5)
Designed forload calibration of voltage transformers with them on a zero-differential unit in AC circuits of frequency 50Hz or 60Hz;
Acceptable basic error limit of active and reactive power components of the conductivity or - 4%;
Rated voltage - 100V;
Voltage measurement range - 20% -120% of nominal voltage;
Rated power factor - 1;
The nominal value of the total power levels - 1.25 ∙ A ∙ A 2.5 V, 5 V ∙ A ∙ A 10V, 15V ∙ A.

More info ...

R5054/6 (p5054/6)

19 999 RUB   |   9 600 UAH   |  available: 1 piece
Most conductivity R5054 / 6.
Conductivity bridge R5054/6 (R50546, R 5054 6, R-5054-6, p5054 / 6, R5054-6, R5054 6, p50546, p 5054 6, p-5054-6, p5054-6, p5054 6)
Designed forload calibration of voltage transformers with them on a zero-differential unit in AC circuits of frequency 50Hz or 60Hz;
Acceptable basic error limit of active and reactive power components of the conductivity or - 4%;
Rated voltage - 150V;
Voltage measurement range - 20% -120% of nominal voltage;
Rated power factor - 0,8, 1;
The nominal value of the total power levels - 1.25 ∙ A ∙ A 2.5 V, 5 V ∙ A ∙ A 10V, 15V ∙ A.

More info ...

UPIP-60M

35 699 RUB   |   14 280 UAH   |  available: 6 pieces
Universal measuring instrument TVSS-60M.
The device is a universal measuring UPIP-60M (UPIP60M, UPIP-60-M, UPIP 60 M, UPIP 60M)
The range of resistance measurements - 10 -4 ohm-10 6 ohms;
Class of accuracy of the instrument as a potentiometer - 0.05;
Accuracy class of the device as a bridge - 0.1.

More info ...