Laboratory equipment >> freight piston pressure manometers

КГП-1

396 000 RUB   |   82 500 UAH
HC-1  photo of the device.

Манометр грузопоршневой КГП-1, кл.0,02


More info ...

КГП-2,5

397 400 RUB   |   82 800 UAH
HC-2, 5  photo of the device.

Манометр грузопоршневой КГП-2,5, кл.0,02


More info ...

MVP-2,5 cl.0,02 (МВП-2,5)

149 999 RUB   |   59 999 UAH   |  available: 1 piece
pressure vacuum gauge deadweight MVP-2,5.
Deadweight compound pressure and vacuum gauge MVP-2,5 (MVP2,5, MVP 2,5)
Designed for testing strain gauge model with upper limits of measurement is not more than 0.25 MPa (2.5 kgf / cm 2) and reference strain gauges, as well as for the direct measurement of pressure and vacuum;
The limits of pressure:
- Excess - from 0MPa to 0.25 MPa (0kgs/sm 2 to 2.5 kg / cm 2);
- Vacuum - from 0MPa to -0.095 MPa (from 2 to 0kgs/sm -0.95 kgf / cm 2) or 0mm.rt.st. 750mm.rt.st-up.;
Class of accuracy - 0.02.

More info ...

MVP-2,5 cl.0,05 (МВП-2,5)

29 025 RUB   |   7 650 UAH
Manovakuometr deadweight MVP-2, 5.
Deadweight Manovakuometr MVP-2,5 (MVP2,5, MVP 2,5)
Designed for testing strain gauge model with upper limits of measurement is not more than 0.25 MPa (2.5 kgf / cm 2) and reference strain gauges, as well as for the direct measurement of pressure and vacuum;
The limits of pressure:
- Excess - from 0MPa to 0.25 MPa (0kgs/sm 2 to 2.5 kg / cm 2);
- Vacuum - from 0MPa to -0.095 MPa (from 2 to 0kgs/sm -0.95 kgf / cm 2) or 0mm.rt.st. 750mm.rt.st-up.;
Class of accuracy - 0.05.

More info ...

MGP-10

134 461 RUB   |   33 616 UAH
    MGP-10 gas gauge deadweight used as a benchmark for verification and calibration of measuring the excess pressure gauges, transducers, model and technical gauges and other measuring instruments (except oxygen SI) under laboratory conditions.Accuracy class - 0.02, 0.05.
    The upper limit of measurement - 1 MPa (10 kgf/cm2).
    The lower limit of measurement - 0.02 MPa (0.2 kgf/cm2).

More info ...

MGP-100

164 728 RUB   |   41 182 UAH
MGP-100 gas gauge deadweight. Appearance.
    MGP-100 gas gauge deadweight used as a benchmark for verification and calibration of measuring the excess pressure gauges, transducers, model and technical gauges and other measuring instruments (except oxygen SI) under laboratory conditions.Accuracy class - 0.02, 0.05.
    The upper limit of measurement - 10 MPa (100 kgf/cm 2).
    The lower limit of measurement - 0.04 MPa (0.4 kgf/cm 2).

More info ...

MGP-2,5

144 491 RUB   |   36 123 UAH
    MGP-2,5 gas gauge deadweight used as a benchmark for verification and calibration of measuring the excess pressure gauges, transducers, model and technical gauges and other measuring instruments (except oxygen SI) under laboratory conditions.Accuracy class - 0.02, 0.05.
    The upper limit of measurement - 0.25 MPa (2.5 kgf/cm 2).
    The lower limit of measurement - from 0.003 MPa (0.03 kg/cm 2).

More info ...

MGP-V

159 005 RUB   |   39 752 UAH
    MGP-V Gas Gauge deadweight used as a benchmark for verification and calibration of measuring the excess pressure gauges, transducers, model and technical gauges and other measuring instruments (except oxygen SI) under laboratory conditions. Accuracy class - 0.02, 0.05.
    The upper limit of measurement - (-0.1) MPa (-1 kgf/cm 2).
    The lower limit of measurement - from 0.003 MPa (-0.03 kg/cm 2).

More info ...

MGTS-100 cl.0,05 (МГЦ-100)

501 800 RUB   |   104 550 UAH
Digital pressure gauge deadweight MHz-100.
Deadweight Pressure Gauge Digital MGTS-100 (MGTS100, MGTS 100)
Designed for testing strain gauges of accuracy class 0.25 and 0.4 with the conclusion about the value of the measured pressure in the form of a digital display on the scoreboard pressure transducer;
The upper limit of measurement - 10 MPa (100kgs/sm 2);
The lower limit of measurement - 0.04 MPa (0.4 kgf / cm 2);
Class of accuracy - 0.05.

More info ...

MGTS-60 cl.0,05 (МГЦ-60)

Digital pressure gauge deadweight MHz-60.
Deadweight Pressure Gauge Digital MGTS-60 (MGTS60, MGTS 60)
Designed for testing strain gauges of accuracy class 0.25 and 0.4 with the conclusion about the value of the measured pressure in the form of a digital display on the scoreboard pressure transducer;
The upper limit of measurement - 6MPa (60kgs/sm 2);
The lower limit of measurement - 0.04 MPa (0.4 kgf / cm 2);
Class of accuracy - 0.05.

More info ...
Pages: 1 2 3 4    View all
MGP-10MGP-100MGP-2,5
MGP-VMGTS-100 cl.0,05 (МГЦ-100)MGTS-60 cl.0,05 (МГЦ-60)
MGTS-60 cl.0,1 (МГЦ-60)MP-2,5 cl.0,01MP-2,5 cl.0,02 (МП-2,5)
MP-2,5 cl.0,05 (МП-2,5)MP-250MP-2500 cl.0,02 (МП-2500)
MP-2500 cl.0,05 (МП-2500)MP-2500 кл.0,01 (МП-2500)MP-400
MP-6MP-60MP-600
MPAK-15 cl.0,01 (МПАК-15)MPD-100 (МПД-100)MPK-0,4 cl.0,2 (МПК-0,4)
MPM-60 cl.0,02 (МПМ-60)MPM-60 cl.0,05 (МПМ-60)MPP-60 cl.0,02 (МПП-60)
MPP-60 cl.0,05 (МПП-60)MPP-600 cl.0,05 (МПП-600)MVP-2,5 cl.0,02 (МВП-2,5)
MVP-2,5 cl.0,05 (МВП-2,5)PMKM-1 cl.0,005 (ПМКМ-1)PMKM-1 cl.0,01 (ПМКМ-1)
КГП-1КГП-2,5МП-100
МПП-60МППКМ-250ППКМ-600
РЭД-0,6РЭД-6,0РЭД-60


Яндекс цитирования