Radiometric devices >> devices for checking, calibration and metrology

5F5.282.243

available: 4 pieces
5F5.282.243 device image.
    The equivalent capsule microphone 5F5.282.243 (5F5-282-243)
    The equivalent 5F5.282.243 microphone capsule - a product developed for the electric meter calibration before measurement of sound pressure levels.
    Equivalent capacitance capsule - 82pF.
More info ...

V1-12 (B1-12)

34 999 RUB   |   13 999 UAH   |  available: 18 pieces
V1-12 (B1-12) device image.

Differential voltmeter V1-12 for checking voltmeters (V112, V1 12, b1-12, b1 12, b112)

Designed for the issuance of calibrated discrete values ​​of DC voltage and current.
The drift of the output voltage (in percent) for 8 hours is not more than ± (0,001 + 0,0001 Uc / U) for 2000 hours - less than ± (0,004 + 0,0004 Uc / U).
The maximum load current at voltages up to 100V - 110mA at a voltage above 100 V - 11 mA.

More info ...

V1-13

34 999 RUB   |   13 999 UAH   |  available: 9 pieces
V1-13 device image.

Programmable device V1-13 for testing voltmeters (V113, V1 13, b1-13, b1 13, b113)

Designed for testing electrical appliances DC.
The output impedance of 0,001 ohms.
The maximum load current is 110 mA at voltages up to 100 V and 11 mA at a voltage up to 1000V.
The drift of the output voltage (in percent) for 8 hours is not more than ± (0,002 + 0,00015 Uc / U), for 2000 hours no more than ± (0,004 + 0,0004 Uc / U).

More info ...

В1-15

99 999 RUB   |   40 000 UAH   |  available: 2 pieces
device image.

В1-15 установка для поверки вольтметров предназначается для определения погрешности показаний высокочастотных вольтметров.

Диапазон выходных напряжений переменного тока - от 3 мВ до 3 В.

Диапазон частот выходных напряжений - от 30 МГц до 1 ГГц.


More info ...

V1-16

34 999 RUB   |   13 999 UAH   |  available: 4 pieces
V1-16 (B1-16) device image.

Device for testing voltmeters V1-16 (V116, V1 16, b1-16, b1 16, b116)

Designed for checking AC voltmeter in a wide range of frequencies.
Output voltage range 100mkV-3B with nominal rms values ​​corresponding to the number of 0.316-0-4B 0 5V 0 0-6V, 7V-0-0 8B, 9B-1, 1B, 2B, 5B-2, 5V, 3V.
Frequency range 10 Hz Output voltage 50-MHz fixed values ​​10-20-30-40-45-55-100-200-300-400-450-550 Hz 1-2-3-4-4,5-5 , 10-20-30-40-45-100-200-500 5 kHz 1 MHz -3-5-10-15-20-30-50.

More info ...

V1-18 (B1-18)

38 999 RUB   |   31 199 UAH   |  available: 3 pieces
V1-18 (B1-18) device image.
    B1-18 instrument for calibration of voltmeters and calibrators intended for verification and metrological studies of various instruments and devices DC autonomously and as part of automated systems.
    DC voltage range - ± (1 nV - In 11.999999).
    Measuring range:
    - DC voltage - ± (0,1 mV - 1000);
    - Changes DC voltage - ± (0,1 mV - 1000 V) and ± (0,0001-99,9999%).
    Accuracy - 0.001%.

More info ...

В1-18/1

38 999 RUB   |   31 199 UAH   |  available: 2 pieces

В1-18/1 вольтметр-калибратор постоянного тока представляет собой образцовый прецизионный прибор, предназначенный для поверки и метрологических исследований широкой номенклатурной группы приборов постоянного тока как в составе автоматизированных систем, взаимодействующих через канал общего пользования, так и автономно.

Диапазон воспроизведения напряжений постоянного тока - от ±1 мкВ до ±11,999999 В.

Диапазон измерения напряжений постоянного тока - от ±0,1 мкВ до ±1000 В.


More info ...

В1-18А/1

В1-18А/1 вольтметр-калибратор постоянного тока представляет собой образцовый прецизионный прибор, предназначенный для поверки и метрологических исследований широкой номенклатурной группы приборов постоянного тока как в составе автоматизированных систем, взаимодействующих через канал общего пользования, так и автономно.

Диапазон воспроизведения напряжений постоянного тока - от ±1 мкВ до ±11,999999 В.

Диапазон измерения напряжений постоянного тока - от ±0,1 мкВ до ±1000 В.


More info ...

V1-19 (B1-19)

69 999 RUB   |   28 000 UAH   |  available: 2 pieces
V1-19 (B1-19) device image.
    Installation for checking voltmeters V1-19 (V1-19; V-1-19, V 1 19; v1-19; v 1-19; v-19 1; B1-19)
    Installation for testing voltmeters V1-19 - calibrated voltage source used for calibration of the basic limits of voltmeters.
    Frequency range - 20Hz - 100kHz.
    Output voltage range AC - 100mkV - 100V, 1000V (with power amplification YA1V-22).
    Allowable load current device - no more than 10A to 5A (1 mV, 10 mV and 100 mV), (Un / Uc) 10A-2A (1B, 10B and 100B).
    Power Consumption - 200W, 1000W (with power amplification YA1V-22).
    Power - power to the unit V1-19 (B1-19) from two different polarities of chemical sources of voltages from 8.5V to 15V (battery or batteries).
    The maximum current consumption of each source - no more than 30 mA.
More info ...

В1-20 установка

available: 2 pieces

В1-20 установка для поверки вольтметров используется для поверки и калибровки высокоточных цифровых и аналоговых электронных вольтметров переменного тока.

Выдача калиброванных напряжений переменного тока - от 10 мкВ до 10 В.


More info ...

V1-25 (B1-25)

34 999 RUB   |   13 999 UAH   |  available: 1 piece
V1-25 (B1-25) voltmeter calibrator image.

    Voltmeter calibrator V1-25 (V1 25, B125, B 1-25, B 1 25; b1-25; b1 25; b125; b 1-25; b 1 25)
    Calibrator V1-25 - the device for verification of measuring instruments DC.
    The range of measured values ​​- from 1 mV to 10V.
    Operating Frequency Range - 1 kHz - 100 kHz.


More info ...

В1-27

89 999 RUB   |   35 999 UAH   |  available: 2 pieces
device scheme.

В1-27 установка для поверки вольтметров предназначена для поверки вольтметров переменного напряжения при автономном пользовании и в составе стационарных и подвижных систем поверки средств измерений.

Диапазон частот - от 20 Гц до 100 кГц.

Диапазон выходных напряжений - от 0,0001 В до 1000 В.


More info ...

В1-27/1

89 999 RUB   |   35 999 UAH   |  available: 2 pieces
device image.

В1-27/1 установка для поверки вольтметров предназначена для поверки вольтметров переменного напряжения при автономном пользовании и в составе стационарных и подвижных систем поверки средств измерений.

Диапазон частот - от 20 Гц до 100 кГц.

Диапазон выходных напряжений переменного тока (среднеквадратическое значение) - от 0,0001 В до 1000 В.


More info ...

V1-28

149 999 RUB   |   59 999 UAH   |  available: 3 pieces
V1-28 device image.

Calibrator-voltmeter V1-28 (V128, V1 28, b1-28, b128, b1 28)

To play and measure resistance, voltage and constant and sinusoidal current.  
The playback range: ± (0.1mkV - 1000V)
Measurement range: ± (1mkV - 1000V)

More info ...

В1-29 калибратор

device scheme.

В1-29 калибратор переменного напряжения предназначен для определения погрешности широкополосных вольтметров и измерителей уровня.

Диапазон частот - от 10 Гц до 100 МГц.

Диапазон выходных напряжений - от 3 мкВ до 3 В.


More info ...

В1-3 установка

available: 2 pieces

Установка В1-3 предназначена для снятия частотных характеристик ламповых вольтметров.

Диапазон частот - от 30 Гц до 30 МГц.

Погрешность установки частоты - не более ±1%.


More info ...

В1-30

29 200 RUB   |   6 080 UAH   |  available: 2 pieces

В1-30 мера напряжения предназначена для передачи размера единицы напряжения постоянного тока от образцовых мер измерительным приборам.

Воспроизводимое напряжение - 9±0,45 В.

Нестабильность воспроизводимого напряжения за каждые 1000 ч при температуре среды 20±5° С - 0,0005%.

Дополнительная температурная погрешность - 0,000025 %/° С.


More info ...

В1-4

available: 2 pieces

В1-4 установка для поверки вольтметров дает возможность с высокой точностью производить поверку электронных вольтметров, милливольтметров и микровольтметров.

Входное сопротивление - не менее 100 кОм.

Выходное напряжение - от 10 мкВ до 300 В.


More info ...

V1-5 (B1-5)

9 000 RUB   |   2 460 UAH   |  available: 2 pieces
V1-5 (B1-5) сalibrator image.

Calibrator V1-5 (B1-5, 1-V-5, V 1; 5 5 V1; v1-5; v 1-5; v-5-1; v 5 1; v1 5)
Calibrator V1 5 - a product for generating a single output sequence of the switching of polarity.
The pulse repetition period - 1mks-1000mks.
The amplitude of the pulse - 0.1 V - 100V.
Pulse frequency - 0.1 Hz - 1 kHz.


More info ...

В1-6 установка

available: 2 pieces

В1-6 установка для проверки вольтметров предназначена для определения погрешности электронных вольтметров переменного тока, служит также источником стабилизированных переменных напряжений синусоидальной формы с высокой точностью установки амплитуды с малыми нелинейными искажениями.

Диапазон выходного напряжения - от 100 мкВ до 3000 мВ.

Диапазон частот - от 10 Гц до 10 Гц.


More info ...

В1-7 прибор для поверки вольтметров

available: 3 pieces

В1-7 прибор для поверки вольтметров предназначен для выдачи калиброванных напряжений с целью обеспечения поверки цифровых вольтметров постоянного тока, а также вольтметр может измерять величины и нестабильности напряжений постоянного тока.

Диапазон выходного напряжения - от 0 до 1000 В.

Ток нагрузки - от 10 мкА до 1 мА.


More info ...

В1-71

47 990 RUB   |   10 000 UAH
Прибор для поверки вольтметров В1-71
More info ...

В1-71/1

70 830 RUB   |   14 760 UAH
Прибор для поверки вольтметров В1-71/1
More info ...

V1-8

18 999 RUB   |   7 599 UAH   |  available: 8 pieces
V1-8 device image.

Installation for testing voltmeters V1-8 (V 1-8, V-1-8, b1-8, b-1-8, b 1-8)

Is designed to determine the error of indication of analog voltmeter AC and DC subband of 10mkV to 300V in the laboratory.

More info ...

V1-9

49 999 RUB   |   19 999 UAH   |  available: 7 pieces
V1-9 voltmeter image.

Differential voltmeter V1-9 for verification voltmeters (V19, V1 9, b1-9, b1 9, b19)

It is intended for testing and voltmeters AC converters.
Output range 100mkV-100B (1-10-100mV - 1 - 10-100B)
Frequency response 20Hz-100kHz (overlapping with manual control sub-bands: 20-100, 100-1000Hz, 1-10, 10-100kHz)

More info ...

Г1-2 установка

available: 1 piece

Г1-2 установка для калибровки генераторов шума предназначена для измерения относительной шумовой температуры генераторов шума методом сравнения с характеристиками образцового генератора шума.

Диапазон частот измерения - от 0,4 ГГц до 4 ГГц.

Волновое сопротивления (канал 16/6,95 мм) - 50 Ом.


More info ...

И1-10 измеритель

99 999 RUB   |   40 000 UAH   |  available: 2 pieces

И1-10 измеритель мгновенных напряжений импульсный предназначен для настройки, контроля и поверки радиотехнических устройств.

Диапазоны измерения мгновенных напряжений:

- для 10 В - от 0,1 В до 9,95 В;

- для 100 В - от 9,95 В до 99,5 В;

- с внешним источником компенсационного напряжения - от 10 В до 150 В.


More info ...

I1-11

8 442 RUB   |   4 896 UAH
Generator test pulses I1-11.
Generator test pulses I1-11 (I111, I-1-11, I 1 11, I1 11)
Designed to test the PH Y-channels oscilloscope to 10MHz;
Duration
- Front - ≤ 10 ns (mode 1), ≤ 0,1 ms (mode 2);
- Cut - ≤ 100ns (mode 1), ≤ 0,5 ms (mode 2).
The pulse duration - 1 ms-100mks (mode 1), 0.05 ms-5 ms and up to 10000ms with a single start-up (mode 2).
Amplitude into 50 ohms: 0,005 B-65V (mode 1), 0.05-6B (mode 2).
The pulse repetition period - 0.1 ms, 10 ms (mode 1 and 2).
Delay relative to the main clock pulses - 0.03 ms-1mks (mode 1), 0.1 ms-1mks (rezhim2).

More info ...

И1-12 генератор

39 999 RUB   |   16 000 UAH   |  available: 1 piece
I1-12 device image.
   И1-12 генератор перепада напряжения предназначен для проверки переходной характеристики сверхширокополосных стробоскопических осциллографов.

Длительность фронта перепада напряжения - от 50 пс до 120 пс.

Внешняя нагрузка - 50±1 Ом.

More info ...

I1-14

99 999 RUB   |   40 000 UAH   |  available: 1 piece
I1-14 calibrator image.
Calibrator pulse I1-14 (I114, I-1-14, I 1 14, I1 14)
Applied in the development, serial production and operation of broadband oscilloscopes, as well as to test the linear four-HRP (video amplifier, dividers, etc.);
Rise time - ≤ 1 ns;
Ejection at the top - ≤ 3%;
Uneven top - ≤ (1-3)%;
The maximum amplitude of the pulse - ≥ 20V;
Accuracy of the amplitude - 0,1 U;
Smoothly-stage pulse amplitude attenuation - 0dB-63dB;
The pulse duration - 0.1 ms-10mks;
Accuracy duration - 0,1 t +0,01 us;
The pulse repetition period - 0.01 ms-100mkc;
Accuracy of period - 0.1 T.

More info ...

I1-15

99 999 RUB   |   40 000 UAH   |  available: 2 pieces
I1-15 calibrator image.
Calibrator pulse I1-15 (I115, I-1-15, I 1 15, I1 15)
Applied in the development, serial production and operation of broadband oscilloscopes, as well as to test the linear four-HRP (video amplifier, dividers, etc.);
Rise time - ≤ 0,25 ns;
Ejection at the top - ≤ 3%;
Uneven top - ≤ (1-3)%;
The maximum amplitude of the pulse - ≥ 10 V;
Accuracy of the amplitude - 0,1 U;
Smoothly-stage pulse amplitude attenuation - 0dB-43dB;
The pulse duration - 0.1 ms-10mks;
Accuracy duration - 0,1 t +0,01 us;
The pulse repetition period - 0.01 ms-100mkc;
Accuracy of period - 0.1 T.

More info ...

И1-16 генератор

available: 2 pieces

И1-16 генератор испытательных импульсов предназначен для проверки ПХ вертикального тракта осциллографа с максимальной полосой пропускания до 1000 МГц. Может быть использован для проверки ПХ линейных четырехполюсников.

Длительность фронта - не более 0,15 нс.

Максимальная амплитуда импульса - 10 В.

Погрешность установки амплитуды - 0,1∙U.


More info ...

I1-17

99 999 RUB   |   40 000 UAH   |  available: 2 pieces
Calibrator I1-17.
Calibrator I1-17 (I117, I-1-17, I 1 17, I1 17)
Designed to work as part of the AIS or as a standalone device for checking PF U-channels oscilloscope 1-4th class of accuracy in the frequency range 10MHz-0MGts;
The instrument can measure the following parameters of HRP: the rise time, settling time, the release on top of the slope and uneven peaks.

More info ...

И1-18 генератор

99 999 RUB   |   40 000 UAH   |  available: 4 pieces
И1-18 device image.

И1-18 генератор испытательных импульсов предназначен для автоматизированных измерительных систем метрологического обеспечения проверки параметров ПХ осциллографов классов точности от 2 до 4 с полосой частот от 0 до 100 МГц и применяется при их разработке, серийном выпуске и проверке в процессе эксплуатации.

Период импульсов при внутреннем запуске регулируется дискретно - от 0,01 мс до 99,99 мс.

Дискретность регулирования - 0,01 мс.


More info ...

И1-7 формирователь импульсов

available: 3 pieces
device scheme.

И1-7 формирователь импульсов предназначен для формирования импульсных сигналов прецизионной амплитуды.

Длительность прямоугольных импульсов - 5 нс; 10 нс; 30 нс; 0,1 мкс.

Длительность фронта импульсов - не более 0,5 нс.

Диапазон амплитуд импульсов - от 10 мВ до 10 В.

Частота следования импульсов - от 20 Гц до 100 Гц.


More info ...

И1-8

available: 2 pieces

И1-8 источник временных сдвигов с внешним и внутренним запуском служит для измерения параметров измерителей временных интервалов и другой радиоэлектронной аппаратуры.

Диапазон измерения - от 0 с до 1 с.

Частота повторения выходных импульсов - от 1·10-3 кГц до 100 кГц.


More info ...

I1-9

19 999 RUB   |   8 000 UAH   |  available: 4 pieces
Oscilloscope сalibrator I1-9 pulsed .

Oscilloscope сalibrator I1-9 pulsed (I1 9, I 19)

It is intended for testing and calibration of oscilloscopes with bandwidth up to 100 MHz.
Signal shape - rectangular pulses of positive polarity
Amplitude 30 * 10-6 -100 increments to set U = (lm * 10n) B, where l = 3, 4, 5, 6, 8, 10; n = -5, -4 -3, -2 , -1, 0
Setting error in calibration mode (into 1 M) ± 2,5 * 10 -3 +3 mV Uc

More info ...

IONA voltage source

18 000 RUB   |   5 625 UAH   |  available: 3 pieces
IONA device image.

IONA reference voltage source autonomous is intended for periodic inspection and calibration of devices.

The output voltage Uout - 9.1 V±5%.


More info ...

IPU-01M

34 999 RUB   |   13 999 UAH   |  available: 1 piece
IPU-01M device image.
Setting a model for testing of IPU-01M (IPU01M, IPU 01 M, IPU-01-M, IPU 01M)
It is intended to check and adjust the measuring, regulating and recording devices of heat and power control.

More info ...

К6-12 АРМ поверки

20 300 000 RUB   |   9 202 667 UAH
device image.

К6-12 АРМ поверки НАП предназначено для автоматизированной поверки НАП путем передачи ей размера единиц величин координат, частоты и времени.

Диапазон формирование сигналов ГЛОНАСС - L1; L2; CT-код; BT-код.

Диапазон формирование сигналов GPS - L1; C/A-код.

Число каналов формирования сигналов ГЛОНАСС и GPS - не менее 24.


More info ...

М1-25 прибор

499 999 RUB   |   240 000 UAH   |  available: 3 pieces
device image.

М1-25 прибор для поверки ваттметров предназначен для градуировки, первичной и периодической поверки ваттметров и первичных приемных преобразователей СВЧ-сигналов.

Диапазон частот - от 37,5 ГГц до 78,33 ГГц.

Сечение волноводного тракта - 5,2×2,6 мм; 3,6×1,8 мм.


More info ...

М1-25/1 прибор

499 999 RUB   |   240 000 UAH   |  available: 2 pieces
device image.

М1-25/1 прибор для поверки ваттметров предназначен для градуировки, первичной и периодической поверки ваттметров и первичных приемных преобразователей СВЧ-сигналов.

Диапазон частот - от 37,5 ГГц до 53,57 ГГц.

Сечение волноводного тракта - 5,2×2,6 мм.


More info ...

М1-25/2 прибор

499 999 RUB   |   240 000 UAH   |  available: 2 pieces
device image.

М1-25/2 прибор для поверки ваттметров предназначен для градуировки, первичной и периодической поверки ваттметров и первичных приемных преобразователей СВЧ-сигналов.

Диапазон частот - от 53,57 ГГц до 78,83 ГГц.

Сечение волноводного тракта - 3,6×1,8 мм.


More info ...

МК8518

Calibrated signal source frequency MK8518.
Источник калиброванных сигналов частоты МК8518

Источник калиброванных сигналов частоты, основная погрешность ±0,001%

 


More info ...

Н7-2 установка

available: 3 pieces

Н7-2 установка для поверки ваттметров предназначена для поверки ваттметров.

Диапазон частот - от 37,5 ГГц до 53,57 ГГц.

Размеры волновода - 5,2×2,6 мм.

Пределы доп. погрешности  установки частоты - ±0,2 %.


More info ...

Н7-3 установка

available: 3 pieces

Н7-3 установка предназначена для поверки ваттметров с погрешностью измерения мощности.

Диапазон частот - от 53,57 ГГц до 78,33 ГГц.

Погрешность измерение мощности - не менее ±3%.

Максимальный уровень мощности калибровки - от 5 мВт до 10 мВт.


More info ...

ОК6-13

available: 1 piece

ОК6-13 АРМ поверки средств измерений параметров волоконно-оптических систем передачи предназначено для проведения автоматизированной поверки средств измерений волоконно-оптические системы передачи по параметрам мощности, спектральных характеристик и времени задержки и ослабления сигнала в линии.

Рабочие длины волн источника излучения ОГ4-223, аттенюатора программируемого ОД1-28, генератора импульсов поверочного ОГ5-101, волокна оптического - 0,85 мкм; 1,31 мкм; 1,55 мкм.

Диапазон длин волн ваттметра ОМ3-109 и установки для спектральных измерений ОС4-100 - от 0,8 мкм до 1,65 мкм.


More info ...

СК2-13

available: 1 piece

СК2-13 измеритель качественных показателей АМ сигналов вещательных передатчиков предназначен для контроля модуляционных параметров АМ вещательных передатчиков в радиоцентрах и лабораториях: коэффициента нелинейных искажений, уровня шума и фона, частотной характеристики тракта.

Диапазон частот:

- несущих - от 0,15 МГц до 30 МГц;

- модулирующих - от 30 Гц до 15 кГц.

Диапазон модулирующих частот - от 0,03 кГц до 15 кГц.


More info ...

СК2-15 прибор для проверки измерителей

available: 3 pieces

СК2-15 прибор для проверки измерителей коэффициентов АМ обеспечивает определение основной и дополнительной погрешности измерения коэффициентов AM и собственного коэффициента гармоник огибающей измерителей коэффициентов AM и комбинированных измерителей AM/ЧМ.

Обеспечивает проверку приборов С2-12, СК3-26, от СК3-39 до СК3-42 при выпуске и эксплуатации.

Несущая частота AM сигнала - 10±0,005 МГц.

Диапазон модулирующих частот - от 0,03 кГц до 500 кГц.


More info ...

SK2-24 (ck2-24)

22 511 RUB   |   13 056 UAH   |  available: 1 piece
TC2-24 meter.
Meter SK2-24 (SK224, SK-2-24, SK 2 24, SK2-24, SK2 24, SK-224, SK 224, ck224, ck-2-24, ck 2 24, ck2 24, ck-224 ck 224)
Designed for precision measurement of AM signals with different transferring equipment, and measurement of generators;
Carrier frequency range:
- 0.01 MHz-500 MHz;
- To 650MGts (external oscillator);
The range of modulating frequencies - 0.02 kHz-200 kHz;
Modes of measurement of the AM - Peak, RMS, average;
Measuring range:
- Coefficient of AM - 0,1% -100%;
- Carrier frequency - 0.01 MHz-500 MHz;
- Frequency modulation - 0.02 kHz-200 kHz;
- Input voltage - 0.1 B-1B;
The limits of the basic error of measurement:
- Coefficient of AM - ± (1,5% -3%);
- Carrier frequency - ± (10 5fs 5 Hz);
- Frequency modulation - ± (10-3F +5 Hz);
- Input voltage - ± 2dB.
 

More info ...

Тестовые газы и принадлежности

Test gases and accessories.
Тестовые газы и принадлежности

Чтобы эффективно контролировать приборы, вам необходимы тестовые и калибровочные газы в надлежащей таре, правильные концентрации и смеси, а так же соответствующие принадлежности, например регуляторы, специальные шланги, и т.д.

 


More info ...

УАПС-1М/Р

859 057 RUB   |   389 439 UAH
device image.

УАПС-1М/Р установка для поверки счетчиков электрической энергии автоматизированная предназначены для автоматизированной поверки статических однофазных и трехфазных счетчиков, измеряющих активную и реактивную энергию в двух направлениях.

Класс поверяемых счетчиков:

- активной энергии - 1 и менее;

- реактивной энергии - 2 и менее.

Основная приведенная погрешность установки напряжений и токов - не более ±0,3%.


More info ...

УПП8531М/1

Installing a portable calibration UPP8531M / 1.
Установка поверочная переносная УПП8531М/1

для поверки стрелочных и цифровых амперметров, вольтметров, однофазных ваттметров, трехфазных ваттметров и варметров, ИП переменного тока, ИП напряжения переменного тока, ИП активной и реактивной мощности 2-х и 3-х элементных,  канала телемеханики, основная погрешность ±0,15%

 


More info ...

УПП8531М/2

Установка поверочная переносная УПП8531М/2

для поверки стрелочных и цифровых трехфазных ваттметров и варметров, ИП активной и реактивной мощности 2-х и 3-х элементных,  канала телемеханики, основная погрешность ±0,15%

 


More info ...

УПП8531М/3

Installing a portable calibration UPP8531M / 3.
Установка поверочная переносная УПП8531М/3

для поверки стрелочных и цифровых амперметров, вольтметров, однофазных ваттметров, ИП переменного тока,  ИП напряжения переменного тока,  канала телемеханики, основная погрешность ±0,15%

 


More info ...

УПП8531М/4

Installing a portable calibration UPP8531M / 4.
Установка поверочная переносная УПП8531М/4

для поверки стрелочных и цифровых вольтметров, ИП напряжения переменного тока,   основная погрешность ±0,15%

 


More info ...

УПП8531М/5

Installing a portable calibration UPP8531M / 5.
Установка поверочная переносная УПП8531М/5

для поверки стрелочных и цифровых амперметров, ИП переменного тока, основная погрешность ±0,15%

 


More info ...

УПП8556

Installation verification UPP8556.
Установка поверочная УПП8556

Установка поверочная переносная для поверки аналоговых каналов телемеханики, а также измерительных преобразователей постоянного тока и сумматоров, основная погрешность выходного сигнала УПП ±0,05%,  основная погрешность входного сигнала УПП ±0,05%., питание от аккумуляторов и сети ~220 В, 50 Гц

 


More info ...

Ya1V-13

available: 2 pieces
Ya1V-13 block image.

Ya1V-13 measuring unit is designed to measure DC voltage in conjunction with a digital voltmeter universal V7-23.

Measuring range - from 1 mcV to 12 mV.


More info ...

YA1V-22

14 499 RUB   |   5 799 UAH   |  available: 8 pieces
YA1V-22 device image.
Unit voltage gain YA1V-22 (YA1V22, YA-1V-22, YA 1V 22, YA1V 22)
Designed to improve the output voltage of the device for calibration of voltmeters AC B1-9 up to 1000 volts at their joint work.

More info ...
СК2-13К6-12М1-25/2
В1-27/1М1-25/1М1-25
Н7-2Н7-3В1-15
И1-8В1-4В1-18/1
И1-10В1-29Г1-2
УАПС-1М/РВ1-7СК2-15
И1-7ОК6-13В1-6
И1-165F5.282.243I1-11
И1-12I1-14I1-15
I1-17I1-9IONA
IPU-01MSK2-24 (ck2-24)V1-12 (B1-12)
V1-13V1-16V1-18 (B1-18)
В1-18А/1V1-19 (B1-19)V1-25 (B1-25)
В1-27V1-28В1-3
V1-5 (B1-5)V1-8V1-9
YA1V-22Ya1V-13В1-20
В1-30В1-71В1-71/1
И1-18МК8518Тестовые газы и принадлежности
УПП8531М/1УПП8531М/2УПП8531М/3
УПП8531М/4УПП8531М/5УПП8556


Яндекс цитирования