Datasheets and radio parts >> connectors radio-frequency >> coaxial transitions E2 >> coaxial transitions, couplings, adapters

transitions E2-...

available: 1 330 pieces
E2-26 transition image.

Coaxial transition (coaxial adapter) - a combination of the two coaxial connectors connected short rigid coaxial line segment.

Adapters are designed to splice coaxial cables together or to interface coax circuits with different cross-section of the channel. Besides coaxial, there coaxial waveguide and coaxial-strip transitions used for interfacing the coaxial waveguide channels or strip line.


More info ...

Э2-1 переход

available: 14 pieces
device image.

Э2-1 переход коаксиальный измерительный предназначен для соединения коаксиального кабеля с оборудованием или для сочленения двух коаксиальных кабелей друг с другом с различным сечением канала.

Сочленение перехода - резьбовое.

Тип - межканальный.


More info ...

E2-10 (SR-75-220, CP-75-220)

available: 11 pieces
E2-10 (SR-75-220, CP-75-220) transition image.
    Coaxial transition E2-10 (SR-75-220) is designed to connect the measuring coaxial paths that end connectors connecting series 9V-9V, the measurements of various kinds.
    Operating frequency range transitions - 0.5-3 GHz.
    Electrical length of the transitions (joints) - 69 mm.
    Voltage standing wave ratio (VSWR) transitions at frequencies up to 3 GHz - 1.1.

More info ...

E2-11 (SR-50-221)

available: 16 pieces
E2-11 (SR-50-221) device image.

    Coaxial transition E2-11 (SR-50-221) is designed for measuring coaxial connection paths that end connectors connecting rows 8P-8P, the measurements of various kinds.
    Characteristic impedance - 50 ohms.
    The maximum operating frequency of transitions E2-11 (SR-50-221) - up to 7.5 GHz.
    Types of channels - II - II.


More info ...

E2-111/1

available: 16 pieces
E2-111/1 transition image.

    E2-111/1 coaxial transition - a set of two coaxial connectors connected short rigid coaxial line segment. Transitions E2-111/1 are used to splice coaxial cables together or to negotiate coax circuits with different cross-section of the channel.

    Characteristic impedance transitions E2-111/1 - 50 ohms.
    Types of channels - III - II.
    Frequency - up to 7.5 GHz.

More info ...

E2-111/2

available: 12 pieces
E2-111/2 transition image.
    E2-111/2 coaxial transition - a set of two coaxial connectors connected short rigid coaxial line segment. Transitions E2-111/2 are used to splice coaxial cables together or to negotiate coax circuits with different cross-section of the channel.
    Characteristic impedance transitions E2-111/2 - 50 ohms.
    Types of channels - III - II.

More info ...

E2-111/3

available: 24 pieces
E2-111/3 transition image.
    E2-111/3 coaxial transition - a set of two coaxial connectors connected short rigid coaxial line segment. Transitions E2-111/3 used to splice coaxial cables together or to negotiate coax circuits with different cross-section of the channel.
    Characteristic impedance transitions E2-111/3 - 50 ohms.
    Types of channels - III - II.
    Frequency - up to 7.5 GHz.

More info ...

E2-111/4

available: 38 pieces
E2-111/4 transition image.
    E2-111/4 coaxial transition - a set of two coaxial connectors connected short rigid coaxial line segment. Transitions E2-111/4 are used to splice coaxial cables together or to negotiate coax circuits with different cross-section of the channel.
    Characteristic impedance transitions E2-111/4 - 50 ohms.
    Types of channels - III - II.
    Frequency - up to 7.5 GHz.

More info ...

E2-112/1

available: 16 pieces
E2-112/1 transition image.

    E2-112/1 coaxial transition - a set of two coaxial connectors connected short rigid coaxial line segment. Transitions E2-112/1 are used to splice coaxial cables together or to negotiate coax circuits with different cross-section of the channel.

    Characteristic impedance transitions E2-112/1 - 50 ohms.
    Types of channels - III - III.
    Frequency - up to 18 GHz.

More info ...

E2-112/2

available: 15 pieces
E2-112/2 transition image.

    E2-112/2 coaxial transition - a set of two coaxial connectors connected short rigid coaxial line segment. Transitions E2-112/2 are used to splice coaxial cables together or to negotiate coax circuits with different cross-section of the channel.

    Characteristic impedance transitions E2-112/2 - 50 ohms.
    Types of channels - III - III.
    Frequency - up to 18 GHz.

More info ...

E2-113/1

available: 25 pieces
E2-113/1 transition image.
    E2-113/1 coaxial transition - a set of two coaxial connectors connected short rigid coaxial line segment. Transitions E2-113/1 are used to splice coaxial cables together or to match coaxial sections with different cross-section of the channel.
    Characteristic impedance transitions E2-113/1 - 50 ohms.
    Channel Types - III - I V.
    Frequencies - 3 GHz.

More info ...

E2-113/2

available: 15 pieces
E2-113/2 transition image.
    E2-113/2 coaxial transition - a set of two coaxial connectors connected short rigid coaxial line segment. Transitions E2-113/2 are used to splice coaxial cables together or to negotiate coax circuits with different cross-section of the channel.
    Characteristic impedance transitions E2-113/2 - 50 ohms.
    Types of channels - III - I V.
    Frequencies - 3 GHz.

More info ...

E2-113/3

available: 18 pieces
E2-113/3 transition image.
    E2-113/3 coaxial transition - a set of two coaxial connectors are connected short rigid coaxial line segment. Transitions E2-113/3 are used to splice coaxial cables to each other or to negotiate coaxial sections with different cross-section of the channel.
    Characteristic impedance transitions E2-113/3 - 50 ohms.
    Channel Types - III - I V.
    Frequencies - 3 GHz.

More info ...

E2-113/4

available: 12 pieces
E2-113/4 transition image.
    E2-113/4 coaxial transition - a set of two coaxial connectors connected short rigid coaxial line segment. Transitions E2-113/4 are used to splice coaxial cables together or to negotiate coax circuits with different cross-section of the channel.
    Characteristic impedance transitions E2-113/4 - 50 ohms.
    Types of channels - III - I V.
    Frequencies - 3 GHz.

More info ...

E2-114/1

available: 11 pieces
E2-114/1 transition image.
    E2-114/1 coaxial transition - a set of two coaxial connectors connected short rigid coaxial line segment. Transitions E2-114/1 are used to splice coaxial cables together or to negotiate coax circuits with different cross-section of the channel.
    Characteristic impedance transitions E2-114/1 - 50 ohms.
    Types of channels - III - V.
    Frequencies - 10 GHz.

More info ...

E2-114/2

available: 11 pieces
E2-114/2 transition image.
    E2-114/2 coaxial transition - a set of two coaxial connectors connected short rigid coaxial line segment. Transitions E2-114/2 are used to splice coaxial cables together or to negotiate coax circuits with different cross-section of the channel.
    Characteristic impedance transitions E2-114/2 - 50 ohms.
    Types of channels - III - V.
    Frequencies - 10 GHz.

More info ...

E2-114/3

available: 31 pieces
E2-114/3 transition image.

    E2-114/3 coaxial transition - a set of two coaxial connectors connected short rigid coaxial line segment. Transitions E2-114/3 used to splice coaxial cables together or to negotiate coax circuits with different cross-section of the channel.

    Characteristic impedance transitions E2-114/3 - 50 ohms.
    Types of channels - III - V.
    Frequencies - 10 GHz.

More info ...

E2-114/4

available: 33 pieces
E2-114/4 transition image.

    E2-114/4 coaxial transition - a set of two coaxial connectors connected short rigid coaxial line segment. Transitions E2-114/4 are used to splice coaxial cables together or to negotiate coax circuits with different cross-section of the channel.

    Characteristic impedance transitions E2-114/4 - 50 ohms.
    Types of channels - III - V.
    Frequencies - 10 GHz.

More info ...

E2-115/1

available: 14 pieces
E2-115/1 transition image.

    E2-115/1 coaxial transition - a set of two coaxial connectors connected short rigid coaxial line segment. Transitions E2-115/1 are used to splice coaxial cables together or to negotiate coax circuits with different cross-section of the channel.

    Characteristic impedance transitions E2-115/1 - 50 ohms.
    Types of channels - III - VI.
     Frequencies - 10 GHz.

More info ...

E2-115/2

available: 25 pieces
E2-115/2 transition image.
    E2-115/2 coaxial transition - a set of two coaxial connectors connected short rigid coaxial line segment. Transitions E2-115/2 are used to splice coaxial cables together or to negotiate coax circuits with different cross-section of the channel.
    Characteristic impedance transitions E2-115/2 - 50 ohms.
    Types of channels - III - VI.
    Frequencies - 10 GHz.

More info ...

E2-115/3

available: 30 pieces
E2-115/3 transition image.
    E2-115/3 coaxial transition - a set of two coaxial connectors connected short rigid coaxial line segment. Transitions E2-115/3 used to splice coaxial cables together or to negotiate coax circuits with different cross-section of the channel.
    Characteristic impedance transitions E2-115/3 - 50 ohms.
    Types of channels - III - VI.
    Frequencies - 10 GHz.

More info ...

E2-115/4

available: 93 pieces
E2-115/4 transition image.
    E2-115/4 coaxial transition - a set of two coaxial connectors connected short rigid coaxial line segment. Transitions E2-115/4 are used to splice coaxial cables together or to negotiate coax circuits with different cross-section of the channel.
    Characteristic impedance transitions E2-115/4 - 50 ohms.
    Types of channels - III - VI.
    Frequencies - 10 GHz.

More info ...

Э2-117/2

available: 2 pieces

Э2-117/2 переход коаксиальный - совокупность из двух коаксиальных разъёмов, соединённых коротким жестким отрезком коаксиальной линии.


More info ...

E2-12 (SR-75-222)

available: 13 pieces
E2-12 (SR-75-222) transition image.

    Coaxial transition E2-12 (SR-75-222) is designed for measuring coaxial connection paths that end connectors connecting rows 9P-9P, the measurements of various kinds.
    Characteristic impedance - 75 ohms.
    The maximum operating frequency of transitions E2-12 (SR-75-222) - up to 3 GHz.
    Channel Types - VIII - VIII.


More info ...

E2-13 (SR-50-223)

available: 37 pieces
E2-13 (SR-50-223) transition image.

    Coaxial transition E2-13 (SR-50-223) is designed for measuring coaxial connection paths that end with the connectors connecting the series 8B-7R, the measurements of various kinds.
    Characteristic impedance - 50 ohms.
    The maximum operating frequency of transitions E2-13 (SR-50-223) - up to 7.5 GHz.
    Types of channels - II - VI.


More info ...

E2-14 (SR-50-224)

available: 18 pieces
E2-14 (SR-50-224) device image.

 

    Coaxial transition E2-14 (SR-50-224) is designed for measuring coaxial connection paths that end connectors connecting rows 8P-7V, the measurements of various kinds.    Characteristic impedance - 50 ohms.
    The maximum operating frequency of transitions E2-14 (SR-50-224) - up to 7.5 GHz.
    Types of channels - II - VI.

 


More info ...

E2-15 (SR-50-225)

available: 15 pieces
E2-15 (SR-50-225) transition image.

    Coaxial transition E2-15 (SR-50-225) is designed for measuring coaxial connection paths that end connectors connecting 7P-8P series, measurements of various kinds.
    Characteristic impedance - 50 ohms.
    The maximum operating frequency of transitions E2-15 (SR-50-225) - up to 7.5 GHz.
    Types of channels - II - VI.


More info ...

E2-16 (SR-50-226)

available: 11 pieces
E2-16 (SR-50-226) transition image.

    Coaxial transition E2-16 (SR-50-226) is designed for measuring coaxial connection paths that end with the connectors connecting the series 8B-7B, the measurements of various kinds.
    Characteristic impedance - 50 ohms.
    The maximum operating frequency of transitions E2-16 (SR-50-226) - up to 7.5 GHz.
    Types of channels - II - VI.


More info ...

E2-17 (SR-50-227)

available: 18 pieces
E2-17 (SR-50-227) transition image.

     Coaxial transition E2-17 (SR-50-227) is designed for measuring coaxial connection paths that end with the connectors connecting the series 8B-5P, the measurements of various kinds.
     Characteristic impedance - 50 ohms.
     The maximum operating frequency of transitions E2-17 (SR-50-227) - up to 3 GHz.
     Types of channels - II - IV.


More info ...

E2-18 (SR-50-228)

available: 24 pieces
E2-18 (SR-50-228) transition image.

    Coaxial transition E2-18 (SR-50-228) is designed for measuring coaxial connection paths that end connectors connecting rows 8P-5V, the measurements of various kinds.
    Characteristic impedance - 50 ohms.
    The maximum operating frequency of transitions E2-18 (SR-50-228) - up to 3 GHz.
    Types of channels - II - IV.


More info ...

E2-19 (SR-50-229)

available: 12 pieces
E2-19 (SR-50-229) transition image.

    Coaxial transition E2-19 (SR-50-229) is designed for measuring coaxial connection paths that end connectors connecting 8P-5R series, measurements of various kinds.
    Characteristic impedance - 50 ohms.
    The maximum operating frequency of transitions E2-19 (SR-50-229) - up to 3 GHz.
    Types of channels - II - IV.


More info ...

E2-20 (SR-50-230)

available: 12 pieces
E2-20 (SR-50-230) transition image.

    Coaxial transition E2-20 (SR-50-230) is designed for measuring coaxial connection paths that end with the connectors connecting the series 8V-5V, the measurements of various kinds.
    Characteristic impedance - 50 ohms.
    The maximum operating frequency of transitions E2-20 (SR-50-230) - up to 3 GHz.
    Types of channels - II - IV.


More info ...

E2-21 (SR-75-231)

available: 28 pieces
E2-21 (SR-75-231) transition image.

    Coaxial transition E2-21 (SR-75-231) is designed for measuring coaxial connection paths that end with the series connectors connecting 9V-6R, the measurements of various kinds.
    Characteristic impedance - 75 ohms.
    The maximum operating frequency of transitions E2-21 (SR-50-231) - up to 1 GHz.
    Channel Types - VIII - VII.


More info ...

E2-22 (SR-75-232)

available: 30 pieces
E2-22 (SR-75-232) transition image.
    Coaxial transition E2-22 (SR-75-232) is designed for measuring coaxial connection paths that end connectors connecting rows 9P-6B, the measurements of various kinds.
    Characteristic impedance - 75 ohms.
    The maximum operating frequency of transitions E2-22 (SR-75-232) - up to 1 GHz.
    Channel Types - VIII - VII.

More info ...

E2-23 (SR-75-233)

available: 12 pieces
E2-23 (SR-75-233) transition image.

    Coaxial transition E2-23 (SR-75-233) is designed for measuring coaxial connection paths that end connectors connecting rows 9P-6P, measurements of various kinds.
    Characteristic impedance - 75 ohms.
    The maximum operating frequency of transitions E2-23 (SR-75-233) - up to 1 GHz.
    Channel Types - VIII - VII.


More info ...

E2-24 (SR-75-234)

available: 15 pieces
E2-24 (SR-75-234) transition image.

    Coaxial transition E2-24 (SR-75-234) is designed for measuring coaxial connection paths that end with the series connectors connecting 9V-6B, in the measurements of various kinds.
    Characteristic impedance - 75 ohms.
    The maximum operating frequency of transitions E2-24 (SR-75-234) - up to 1 GHz.
    Channel Types - VIII - VII.


More info ...

E2-25 (SR-50-235, CP-50-235)

available: 21 pieces
E2-25 (SR-50-235) transition image.

    Coaxial transition E2-25 (SR-50-235) is designed for measuring coaxial connection paths that end with the connectors connecting the series 8B-16R, the measurements of various kinds.

    Characteristic impedance - 50 ohms.
    The maximum operating frequency of transitions E2-25 (SR-50-235) - up to 7.5 GHz.
    Types of channels - II - V.

More info ...

E2-26 (SR-50-236)

available: 19 pieces
E2-26 (SR-50-236) transition image.

    Coaxial transition E2-26 (SR-50-236) is designed for measuring coaxial connection paths that end with the connectors connecting the series 8V-16V, the measurements of various kinds.

    Characteristic impedance - 50 ohms.
    The maximum operating frequency of transitions E2-26 (SR-50-236) - up to 7.5 GHz.
    Types of channels - II - V.

More info ...

E2-27 (SR-50-237, CP-50-237)

available: 15 pieces
E2-27 (SR-50-237) transition image.

    Coaxial transition E2-27 (SR-50-237) is designed for measuring coaxial connection paths that end connectors connecting rows 8P-16P, measurements of various kinds.

    Characteristic impedance - 50 ohms.
    The maximum operating frequency of transitions E2-27 (SR-50-237) - up to 7.5 GHz.
    Types of channels - II - V.

More info ...

E2-28 (SR-50-238, CP-50-238)

available: 14 pieces
E2-28 (SR-50-238) transition image.
    Coaxial transition E2-28 (SR-50-238) is designed for measuring coaxial connection paths that end connectors connecting rows 8P-16V, the measurements of various kinds.
    Characteristic impedance - 50 ohms.
    The maximum operating frequency of transitions E2-28 (SR-50-238) - up to 7.5 GHz.
    Types of channels - II - V.

More info ...

E2-29 (SR-50-239, CP-50-239)

available: 11 pieces
E2-29 (SR-50-239, CP-50-239) transition image.

    Coaxial transition E2-29 (SR-50-239) is designed for measuring coaxial connection paths that end with the connectors connecting the series 7P-7R, the measurements of various kinds.

    Characteristic impedance - 50 ohms.
    The maximum operating frequency of transitions E2-29 (SR-50-239) - up to 10 GHz.
    Channel Types - VI - IV.

More info ...

E2-30 (SR-50-240, CP-50-240)

available: 11 pieces
E2-30 (SR-50-240, CP-50-240) transition image.

    Coaxial transition E2-30 (SR-50-240) is designed for measuring coaxial connection paths that end with the connectors connecting the series 7B-7B, the measurements of various kinds.

    Characteristic impedance - 50 ohms.
    The maximum operating frequency of transitions E2-30 (SR-50-240) - up to 10 GHz.
    Channel Types - VI - IV.

More info ...

E2-31 (SR-50-241, CP-50-241)

available: 12 pieces
E2-31 (SR-50-241) transition image.
    Coaxial transition E2-31 (SR-50-241) is designed for measuring coaxial connection paths that end with the connectors connecting the series 7P-7R, the measurements of various kinds.
    Characteristic impedance - 50 ohms.
    The maximum operating frequency of transitions E2-31 (SR-50-241) - up to 10 GHz.
    Channel Types - VI - IV.

More info ...

E2-32 (SR-50-242, CP-50-242)

available: 11 pieces
E2-32 (SR-50-242) transition image.
    Coaxial transition E2-32 (SR-50-242) is designed for measuring coaxial connection paths that end with the connectors connecting the series 7B-7B, the measurements of various kinds.
    Characteristic impedance - 50 ohms.
    The maximum operating frequency of transitions E2-32 (SR-50-242) - up to 10 GHz.
    Channel Types - VI - IV.

More info ...

E2-33 (SR-50-243, CP-50-243)

available: 17 pieces
E2-33 (SR-50-243) transition image.

    Coaxial transition E2-33 (SR-50-243) is designed for measuring coaxial connection paths that end with the connectors connecting the series 7B-5R, the measurements of various kinds.

    Characteristic impedance - 50 ohms.
    The maximum operating frequency of transitions E2-33 (SR-50-243) - up to 3 GHz.
    Channel Types - VI - IV.

More info ...

E2-34 (SR-50-244, CP-50-244)

available: 12 pieces
E2-34 (SR-50-244) transition image.

    Coaxial transition E2-34 (SR-50-244) is designed for measuring coaxial connection paths that end with the connectors connecting the series 7P-5V, the measurements of various kinds.

    Characteristic impedance - 50 ohms.
    The maximum operating frequency of transitions E2-34 (SR-50-244) - up to 3 GHz.
    Channel Types - VI - IV.

More info ...

E2-35 (SR-50-245, CP-50-245)

available: 14 pieces

    Coaxial transition E2-35 (SR-50-245) is designed for measuring coaxial connection paths that end with the connectors connecting the series 7R-5R, the measurements of various kinds.

    Characteristic impedance - 50 ohms.
    The maximum operating frequency of transitions E2-35 (SR-50-245) - up to 3 GHz.
    Channel Types - VI - IV.

More info ...

E2-36 (SR-50-246, CP-50-246)

available: 11 pieces
E2-36 (SR-50-246, CP-50-246) transition image.
    Coaxial transition E2-36 (SR-50-246) is designed for measuring coaxial connection paths that end with the connectors connecting the series 7V-5V, the measurements of various kinds.
    Characteristic impedance - 50 ohms.
    The maximum operating frequency of transitions E2-36 (SR-50-246) - up to 3 GHz.
    Channel Types - VI - IV.

More info ...

E2-37 (SR-50-247, CP-50-247)

available: 15 pieces
E2-37 (SR-50-247) transition image.

    Coaxial transition E2-37 (SR-50-247) is designed for measuring coaxial connection paths that end with the connectors connecting the series 7B-16R, the measurements of various kinds.

    Characteristic impedance - 50 ohms.
    The maximum operating frequency of transitions E2-37 (SR-50-247) - up to 10 GHz.
    Channel Types - VI - V.

More info ...

E2-38 (SR-50-248, CP-50-248)

available: 14 pieces
E2-38 (SR-50-248) transition image.

    Coaxial transition E2-38 (SR-50-248) is designed for measuring coaxial connection paths that end with the connectors connecting the series 7B-16B, the measurements of various kinds.

    Characteristic impedance - 50 ohms.
    The maximum operating frequency of transitions E2-38 (SR-50-248) - up to 10 GHz.
    Channel Types - VI - V.

More info ...

E2-39 (SR-50-249, CP-50-249)

available: 11 pieces
    Coaxial transition E2-39 (SR-50-249) is designed for measuring coaxial connection paths that end with the connectors connecting the series 7P-16P, measurements of various kinds.
    Characteristic impedance - 50 ohms.
    The maximum operating frequency of transitions E2-39 (SR-50-249) - up to 10 GHz.
    Channel Types - VI - V.

More info ...

E2-40 (SR-50-250, CP-50-250)

available: 17 pieces

    Coaxial transition E2-40 (SR-50-250) is designed for measuring coaxial connection paths that end with the connectors connecting the series 7B-16B, the measurements of various kinds.

    Characteristic impedance - 50 ohms.
    The maximum operating frequency of transitions E2-40 (SR-50-250) - up to 10 GHz.
    Channel Types - VI - V.

More info ...

E2-5 (SR-75/50-215, CP-75/50-215)

available: 12 pieces
E2-5 (SR-75/50-215, CP-75/50-215) transition image.
    Coaxial transition E2-5 (SR-75/50-215) measurement is used to connect coaxial paths that end with the series connectors connecting 8.9 V-8, 9V, measurements of various kinds.
    Operating frequency range transitions - 0.5-4 GHz.
    Voltage standing wave ratio (VSWR) of the transitions at a frequency of 4 GHz - 1.03.

More info ...

E2-6 (SR-75/50-216, CP-75/50-216)

available: 11 pieces
E2-6 (SR-75/50-216, CP-75/50-216) transition image.
    Coaxial transition E2-6 (SR-75/50-216) is designed to connect the measuring coaxial paths that end connectors connecting series 5V-5V, the measurements of various kinds.
    Operating frequency range transitions - 2.5-10 GHz.
    Electrical length of the transitions (joints) - 98 mm.
    Voltage standing wave ratio (VSWR) transitions at frequencies up to 10 GHz - 1.3.

More info ...

E2-7 (SR-50-217, CP-50-217)

available: 13 pieces
E2-7 (SR-50-217, CP-50-217) transition image.
    Coaxial transition E2-7 (SR-50-217) is designed to connect the measuring coaxial paths that end connectors connecting series 8.9 R-8, 9R, measurements of various kinds.
    Operating frequency range transitions - 0.5-4 GHz.
    Voltage standing wave ratio (VSWR) transitions at a frequency of 4 GHz - 1.03.

More info ...

E2-8 (SR-50-218, CP-50-218)

available: 28 pieces
E2-8 (SR-50-218, CP-50-218) transition image.
    Coaxial transition E2-8 (SR-50-218) is designed to connect the measuring coaxial paths that end connectors connecting 5R-5R series, measurements of various kinds.
    Operating frequency range transitions - 2.5-10 GHz.
    Electrical length of the transitions (joints) - 97 mm.
    Voltage standing wave ratio (VSWR) transitions at frequencies up to 10 GHz - 1.3.

More info ...

E2-9 (SR-50-219, CP-50-219)

available: 10 pieces
E2-9 (SR-50-219, CP-50-219) transition image.
    Coaxial transition E2-9 (SR-50-219) is designed to connect the measuring coaxial paths that end connectors connecting series 8V-8V, the measurements of various kinds.
    Operating frequency range transitions - 0.5-4 GHz.
    Electrical length of the transitions (joints) - 69 mm.
    Voltage standing wave ratio (VSWR) of the transitions:
    - Speeds up to 3 GHz - 1.1;
    - At up to 10 GHz - 1.2.

More info ...
Э2-1Э2-117/2E2-10 (SR-75-220, CP-75-220)
E2-11 (SR-50-221)E2-111/1E2-111/2
E2-111/3E2-111/4E2-112/1
E2-112/2E2-113/1E2-113/2
E2-113/3E2-113/4E2-114/1
E2-114/2E2-114/3E2-114/4
E2-115/1E2-115/2E2-115/3
E2-115/4E2-12 (SR-75-222)E2-13 (SR-50-223)
E2-14 (SR-50-224)E2-15 (SR-50-225)E2-16 (SR-50-226)
E2-17 (SR-50-227)E2-18 (SR-50-228)E2-19 (SR-50-229)
E2-20 (SR-50-230)E2-21 (SR-75-231)E2-22 (SR-75-232)
E2-23 (SR-75-233)E2-24 (SR-75-234)E2-25 (SR-50-235, CP-50-235)
E2-26 (SR-50-236)E2-27 (SR-50-237, CP-50-237)E2-28 (SR-50-238, CP-50-238)
E2-29 (SR-50-239, CP-50-239)E2-30 (SR-50-240, CP-50-240)E2-31 (SR-50-241, CP-50-241)
E2-32 (SR-50-242, CP-50-242)E2-33 (SR-50-243, CP-50-243)E2-34 (SR-50-244, CP-50-244)
E2-35 (SR-50-245, CP-50-245)E2-36 (SR-50-246, CP-50-246)E2-37 (SR-50-247, CP-50-247)
E2-38 (SR-50-248, CP-50-248)E2-39 (SR-50-249, CP-50-249)E2-40 (SR-50-250, CP-50-250)
E2-5 (SR-75/50-215, CP-75/50-215)E2-6 (SR-75/50-216, CP-75/50-216)E2-7 (SR-50-217, CP-50-217)
E2-8 (SR-50-218, CP-50-218)E2-9 (SR-50-219, CP-50-219)transitions E2-...


Яндекс цитирования