Electrical measuring instruments >> transformers industrial >> current transformers >> 10kV voltage class

TOL-10-IM-2

12 538 RUB   |   15 045 UAH
TOL-10-IM-2 transformer image.
Current transformer TOL-10-IM-2 (TOL10IM2, TOL 10 IM 2, TOL10-IM-2, IM TOL10 2 TOL10IM-2 TOL10IM 2, TOL-10-1M-2, TOL-10-IM-II)
Designed for installation in the Switchgear (CRU), and serves to signal measurement information instrumentation and (or) protection and control, to isolate the circuits of secondary compounds of high-voltage electrical installations AC voltage class up to 10kV 50Hz or 60Hz ;
The number of secondary windings - 2;
Rated voltage - 10kV or 11kV;
Maximum operating voltage - 12kV;
Rated secondary - 1A, 5A;
Rated primary current - 5A, 10A, 15A, 20A, 30A, 40A, 50A, 75A, 80A, 100A, 150A, 200A, 300A, 400A, 600A, 750A, 800A, 1000A, 1200A, 1500A, 2000A;
Accuracy class - 0,5, 0,5 S, 0,2, 0,2 S, 1; 5P, 10P.

More info ...

TOL-10-IM-3

17 390 RUB   |   20 868 UAH
TOL-10-IM-3 transformer image.
Current transformer TOL-10-IM-3 (TOL10IM3, TOL 10 IM 3, TOL10-IM-3, TOL10 IM 3, TOL10IM-3, TOL10IM 3, TOL-10-1M-3, TOL-10-IM-III)
Designed for installation in the Switchgear (CRU), and serves to signal measurement information instrumentation and (or) protection and control, to isolate the circuits of secondary compounds of high-voltage electrical installations AC voltage class up to 10kV 50Hz or 60Hz ;
The number of secondary windings - 3;
Rated voltage - 10kV or 11kV;
Maximum operating voltage - 12kV;
Rated secondary - 1A, 5A;
Rated primary current - 5A, 10A, 15A, 20A, 30A, 40A, 50A, 75A, 80A, 100A, 150A, 200A, 300A, 400A, 600A, 750A, 800A, 1000A, 1200A, 1500A, 2000A;
Accuracy class - 0,5, 0,5 S, 0,2, 0,2 S, 1; 5P, 10P.

More info ...

TOL-10-IM-4

22 553 RUB   |   27 063 UAH
TOL-10-IM-4 transformer image.
Current transformer TOL-10-IM-4 (TOL10IM4, TOL 10 IM 4, TOL10-IM-4, TOL10 IM 4, TOL10IM-4, TOL10IM 4, TOL-10-1M-4, TOL-10-IM-IV)
Designed for installation in the Switchgear (CRU), and serves to signal measurement information instrumentation and (or) protection and control, to isolate the circuits of secondary compounds of high-voltage electrical installations AC voltage class up to 10kV 50Hz or 60Hz ;
The number of secondary windings - 4;
Rated voltage - 10kV or 11kV;
Maximum operating voltage - 12kV;
Rated secondary - 1A, 5A;
Rated primary current - 5A, 10A, 15A, 20A, 30A, 40A, 50A, 75A, 80A, 100A, 150A, 200A, 300A, 400A, 600A, 750A, 800A, 1000A, 1200A, 1500A, 2000A;
Accuracy class - 0,5, 0,5 S, 0,2, 0,2 S, 1; 5P, 10P.

More info ...

TOL-10-М-2

TOL-10-М-2 transformer image.
Current transformer TOL-10-M-2 (TOL10M2, TOL 10 M 2, TOL10-M-2, TOL10 M 2, TOL10M-2, TOL10M 2)
The number of secondary windings - 2;
Rated voltage - 10kV;
Maximum operating voltage - 12kV;
Rated secondary - 5A;
Rated primary current - 2500A, 3000A, 4000A;
Accuracy class - 0,5; 0,5 S, 0,2; 0,2 S.

More info ...

TOL-10-M-3

21 225 RUB   |   25 470 UAH
TOL-10-M-3 transformer image.
Current transformer TOL-10-M-3 (TOL10M3, TOL 10 3, TOL10-M-3, TOL10 M 3, TOL10M-3, TOL10M 3)
The number of secondary windings - 3;
Rated voltage - 10kV;
Maximum operating voltage - 12kV;
Rated secondary - 5A;
Rated primary current - 2500A, 3000A, 4000A;
Accuracy class - 0,5; 0,5 S, 0,2; 0,2 S.

More info ...

TOL-10-M-4

23 880 RUB   |   28 656 UAH
TOL-10-M-4 transformer image.
Current transformer TOL-10-M-4 (TOL10M4, TOL 10 M 4, TOL10-M-4, TOL10 M-4, TOL10M-4, TOL10M 4)
The number of secondary windings - 4;
Rated voltage - 10kV;
Maximum operating voltage - 12kV;
Rated secondary - 5A;
Rated primary current - 2500A, 3000A, 4000A;
Accuracy class - 0,5; 0,5 S, 0,2; 0,2 S.

More info ...

TOLK-10

12 375 RUB   |   14 850 UAH
TOLK-10 transformer image.
Current transformer TOLK-10 (TOLK10, TOLK 10)
Designed for installation in the Switchgear (CRU), and serves to signal measurement information instrumentation and (or) protection and control, to isolate the circuits of secondary compounds of high-voltage electrical installations AC voltage class up to 10kV 50Hz or 60Hz ;
The number of secondary windings - 2;
Rated voltage - 10kV;
Maximum operating voltage - 12kV;
Rated secondary - 5A;
Rated primary current - 10A, 15A, 20A, 30A, 40A, 50A, 75A, 80A, 100A, 150A, 200A, 300A, 400A, 600A;
Accuracy class - 1, 5P, 10P.

More info ...

TOLK-10-1

14 750 RUB   |   17 700 UAH
TOLK-10-1 transformer image.
Current transformer TOLK-10-1 (TOLK101, TOLK 10 1, TOLK-101, TOLK 101, TOLK10-1, TOLK10 1, TOLK-10-I)
Designed for installation in the Switchgear (CRU), and serves to signal measurement information instrumentation and (or) protection and control, to isolate the circuits of secondary compounds of high-voltage electrical installations AC voltage class up to 10kV 50Hz or 60Hz ;
The number of secondary windings - 1;
Rated voltage - 10kV;
Maximum operating voltage - 12kV;
Rated secondary - 1A, 5A;
Rated primary current - 10A, 15A, 20A, 30A, 40A, 50A, 75A, 80A, 100A, 150A, 200A, 300A, 400A, 600A;
Accuracy class - 0,2 S, 0,2, 0,5 S, 0,5, 1, 5P, 10P.

More info ...

TOLK-10-2

10 753 RUB   |   12 903 UAH
TOLK-10-2 transformer image.
Current transformer TOLK-10-2 (TOLK102, TOLK 10 2, TOLK-102, TOLK 102, TOLK10-2, TOLK10 2, TOLK-10-II)
Designed for installation in the Switchgear (CRU), and serves to signal measurement information instrumentation and (or) protection and control, to isolate the circuits of secondary compounds of high-voltage electrical installations AC voltage class up to 10kV 50Hz or 60Hz ;
The number of secondary windings - 1;
Rated voltage - 10kV;
Maximum operating voltage - 12kV;
Rated secondary - 5A;
Rated primary current - 10A, 15A, 20A, 30A, 40A, 50A, 75A, 80A, 100A, 150A, 200A, 300A, 400A, 600A;
Accuracy class - 0,2 S, 0,2, 0,5 S, 0,5.

More info ...

TPL-10-M

26 683 RUB   |   32 019 UAH
TPL-10-M transformer image.
Current transformer TPL-10-M (TPL10M, TPL 10 M, TPL10-M, TPL10 M, TPL-10M, TPL 10M)
Designed for measuring data transmission measurement devices, protection, automation, alarm and control circuits to isolate the secondary connections of high voltage electrical AC 50Hz or 60Hz;
The number of secondary windings - 2;
Rated voltage - 10kV;
Maximum operating voltage - 12kV;
Rated secondary - 1A, 5A;
Rated primary current - 5A, 10A, 15A, 20A, 30A, 40A, 50A, 75A, 80A, 100A, 150A, 200A, 300A, 400A, 600A, 750A, 800A, 1000A;
Accuracy class - 0,5, 0,5 S, 0,2 S, 1, 10P.

More info ...
Pages: 1 2 3 4 5 6 7 8 9    View all
TL-10-2-I-2TL-10-2-I-2-IIITL-10-2-II-3
TL-10-2-II-3-IIITL-10-3-I-2TL-10-3-I-2-III
TL-10-3-II-3TL-10-3-II-3-IIITL-10M-2-I-1
TL-10M-2-I-2TL-10M-2-II-1TL-10M-2-II-2
TL-10M-2-II-3TL-10M-3-I-1TL-10M-3-II-2
TL-10M-3-II-3TL-10M-4-I-2TL-10M-4-II-2
TL-10M-4-II-3TLSH-10TLSH-10-1
TLSH-10-5TLSH-10-6-4TLSH-10-6-5
TLSH-10-6-6TLSH-10-7-4TLSH-10-7-5
TLSH-10-7-6TOL-10-2TOL-10-3
TOL-10-8TOL-10-9-3TOL-10-9-4
TOL-10-I-1TOL-10-I-12TOL-10-I-13
TOL-10-I-14TOL-10-I-15TOL-10-I-16
TOL-10-I-17TOL-10-I-2TOL-10-I-3
TOL-10-I-4TOL-10-I-5TOL-10-I-6
TOL-10-I-7TOL-10-I-8TOL-10-III-2
TOL-10-III-3TOL-10-IM-2TOL-10-IM-3
TOL-10-IM-4TOL-10-M-3TOL-10-M-4
TOL-10-М-2TOLK-10TOLK-10-1
TOLK-10-2TPL-10-MTPL-10-M-1
TPL-10-M-4TPLK-10TPLK-10-1
TPOL-10TPOL-10-1TPOL-10-2
TPOL-10-3TPOL-10-III-1TPOL-10-III-2
TPOL-10M-2TPOL-10M-3TPOL-10M-4
TSHL-10TSHL-10-1TSHLK-10
TSHLK-10-1TSHLP-10TSHLP-10-1
TSHLPK-10TSHLPK-10-1ТЛ-10М-3-I-2


Яндекс цитирования