Laboratory equipment >> flaw detectors (defectoscopes)

ARINA-5 Pulsed X-ray flaw detector ARINA-5.

ARINA-5

For order is possible effectively delivery of any quantity.
Pulsed X-ray flaw detector ARINA-5 (ARINA5, ARINA 5)
 
Pulsed X-ray flaw detector Arin-5 is designed for use as X-ray source in the implementation of non-destructive testing by radiography.
 
Technical characteristics of the devices pulsed x-ray flaw ARINA-5:
 
Ambient temperature - from -40 º C to +50 º C;
Pressure - 101.3 kPa (5.3 kPa/-25, 6kPa) (760mm.rt.st. (+40 Mm.rt.st./-200mm.rt.st.));
Relative humidity - up to 98% at an ambient temperature of +25 º C and at lower temperatures without condensation;
Exposure dose X-ray device pulsed X-ray flaw detector ARINA-5 at a distance of 500 mm ± 20 mm from the front of the X-ray unit in the direct beam in 1.5 minutes - at least 258mkKl/kg (1000mR);
The thickness of the steel, which is available for radiography using X-ray films with fluorescent intensifying screens - 80mm;
The thickness of the steel, which is available for X-rays with high-contrast X-ray film unit pulsed X-ray flaw detector ARINA-5 - 30mm;
Power - single phase AC 220V ± 22V, 50Hz ± 1Hz or 24V battery pack;
Dimensions of the unit pulse X-ray flaw detector ARINA-5:
- X-ray unit - 460h130h185mm;
- Remote Control - 380h270h100mm;
Unit weight pulsed X-ray flaw detector ARINA-5:
- X-ray unit - 6kg;
- Remote Control - 6.8 kg;
The manufacturer guarantees that the quality of the unit pulse X-ray flaw detector ARINA-5 technical requirements specifications provided the customer terms and conditions of storage, transportation, installation, operation, and its specified operational documentation.