Selsyns, rotary transformers, electric motors >> transformers rotating >> 5MVT

5MVT-2-53

available:
2 pieces
For order is possible effectively delivery of any quantity.
Transformer 5MVT-2-53 rotating (5MVT253, 5-MVT-2-53, 5mbt-m-53 5MVT-253, 5MVT 253 5MVT2-53, 5MVT2 53, 5 MW-2-53 5mbt253, 5-mbt-2-53, mbt 5 2 53, 5mbt-253, 5mbt 253, 5mbt2-53, 5mbt2 53, 5, mbt-2-53)
 
Rotary transformers 5MW-2-53 is a two-pole contact four wrapping machine.
Depending on the scheme and the inclusion mode (function) devices rotating transformer 5MVT-2-53 are divided into sine-cosine (Synchro), output voltage which is proportional to the sine (cosine) the angle of rotation of the rotor, and linear (LVT), the output voltage which varies linearly proportional to the angle of ± 60 °.
 
Technical characteristics of the instrument transformers 5MVT-2-53 Rotary:
 
Operation - Synchro, LVT;
Nominal frequency of the excitation voltage instrument transformer 5MVT-2-53 Rotary - 400Hz;
Moment of static friction - 0.0015 Nm
Supply voltage - 30V;
Input impedance transformer idling device 5MVT-2-53 rotating- 500 ohms;
Turns Ratio - 0.560;
Rotary transformers 5MW-2-53 Synchro mode are divided into accuracy classes:
- Transformer 5MVT-2-53 A class of accuracy (A grade. T) has the characteristics:
- Accuracy in repetition TPD - ± 6ugl.min.;
- Error display the sine function - ± 0,02%;
- Asymmetry of null positions of the rotor - ± 1ugl.min.;
- Residual EDS - no more than 0.05%;
- The difference between the coefficients of transformation - 0.031%;
- Transformer 5MVT-2-53 accuracy class B (B cells. T) has the characteristics:
- Accuracy in repetition TPD - ± 6ugl.min.;
- Error display the sine function - ± 0,04%;
- Asymmetry of null positions of the rotor - ± 1,5 ang.;
- Residual EDS - no more than 0.09%;
- The difference between the coefficients of transformation - 0.052%;
- Transformer 5MVT-2-53 accuracy class 0 (0 cells. T) has the characteristics:
- Accuracy in repetition TPD - ± 10 ang.;
- Error display the sine function - ± 0,06%;
- Asymmetry of null positions of the rotor - ± 2ugl.min.;
- Residual EDS - not more than 0.125%;
- The difference between the coefficients of transformation - 0.062%;
- Transformer 5MVT-2-53 1, accuracy class (1st class. T) has the characteristics:
- Accuracy in repetition TPD - ± 10 ang.;
- Error display the sine function - ± 0,10%;
- Asymmetry of null positions of the rotor - ± 3,5 ang.;
- Residual EDS - no more than 0.19%;
- The difference between the coefficients of transformation - 0.107%;
Rotary transformers 5MW-2-53 in the mode of LVT are divided into classes of accuracy:
- Transformer 5MVT-2-53 A class of accuracy (A grade. T) has the characteristics:
- Accuracy in repetition TPD - ± 6ugl.min.;
- Error display the sine function - ± 0,02%;
- Asymmetry of null positions of the rotor - ± 1ugl.min.;
- Residual EDS - no more than 0.05%;
- The difference between the coefficients of transformation - 0.031%;
- Error display a linear relationship - ± 0,2%;
- Transformer 5MVT-2-53 accuracy class B (B cells. T) has the characteristics:
- Accuracy in repetition TPD - ± 6ugl.min.;
- Error display the sine function - ± 0,04%;
- Asymmetry of null positions of the rotor - ± 1,5 ang.;
- Residual EDS - no more than 0.09%;
- The difference between the coefficients of transformation - 0.052%;
- Error display a linear relationship - ± 0,3%;
Magnetic material instrument transformer 5MVT-2-53 Rotary - E42;
Diameter seat - 35C;
The length of the output shaft ends - 72mm;
Outside diameter - 38mm;
Weight of the device rotating transformer 5MVT-2-53 - no more than 0.35 kg;
The manufacturer guarantees the quality of the instrument transformer 5MVT-2-53 rotating the technical requirements specifications subject to user terms and conditions of storage, transportation, installation, operation, established specifications and operational documentation.


Яндекс цитирования