Selsyns, rotary transformers, electric motors >> transformers rotating >> 4MVT

4MVT

For order is possible effectively delivery of any quantity.
Transformer rotating 4MVT (4-MVT, 4 MW, 4mbt, 4-mbt, mbt 4 1)
 
Technical characteristics of the instrument transformers 4MVT rotating:
 
The change of ratio when the ambient temperature at every 40 ° C - 0.15%;
Changing the transformation of the instrument transformer 4MVT rotating when the excitation voltage of - 0.15%;
Residual EDS - 40mV;
Changing the residual emf when exposed to mechanical stress - 0.02%;
Nominal frequency of the excitation voltage instrument transformer 4MVT Rotary - 400Hz;
Operating frequency range of excitation voltage - 380Gts-525Gts;
Supply voltage - 30V;
Input impedance transformer idling device 4MVT rotating- 500 ohms, 1,000 ohms;
Turns Ratio - 0.6, 1.1;
Vibration loads:
- Frequency range - up to 1,000 Hz;
- Acceleration - 75m / s 2;
Shock instrument transformer 4MVT Rotary - 750m / s 2;
Ambient temperature - -60 ° C to +100 º C;
Relative humidity at 40 ° C - 98%;
Weight - 0.36 kg;
Dimensions instrument transformer 4MVT Rotary:
- Length - 70mm;
- Diameter - 38mm;
Warranty life - 1000 hours;
The manufacturer guarantees the quality of the instrument transformer 4MVT rotating the technical requirements specifications subject to user terms and conditions of storage, transportation, installation, operation, established specifications and operational documentation.