Universal digital teslameter 43205
     Designed to measure:
     - radial component of constant magnetic field induction (0-1500mT, ± 0.5%)
     - radial component of sinusoidal RMS form of alternating magnetic field (0-100mT, ± 4%);
     - axial component of constant field induction (0-19.99 mT, ± 2.5%)).
 
Universal Teslameter 43205  (hereinafter the device) is used for measurements: radial component of sinusoidal RMS form of alternating magnetic field with the help ofprimary converter thickness do not exceed 0.95 mm; axial component of constant field induction with the help of  6 mm diameter primary converter.
Connecting primary transducers with input devicesconnector  of Teslameter 43205 is carried out with flexible cables length 1.5 m.
Selecting measurement range and type of measured induction - manual. Polarity of static magnetic field induction determination, and its indication by device Teslameter 43205 - automatic.
Climatic factors values in accordance with GOST 22261-82, group 2 and GOST 15150-69, conditions YXL 4.2. DC and AC magnetic fields radial component induction measured by primary measuring converter PIP-PAD, made ​​in the probe form. Axial induction component of static magnetic field is measured by primary measuring transducer PIP-AKC, made ​​in the probe form.
     Warning! Mechanical force application to measuring parts of primary transducers is unacceptable!
Teslameters 43205 operating conditions are shown in Table 1.  
 
    Teslametrs 43205
 
    Table 1
Influence value
Influencing quantities value
Ambient temperature, ° C
10-35
Relative humidity at 25, ° C,%
80
Atmosphere pressure, kPa (mm Hg)
84 – 106.7 (630-800)
Voltage supply, V
198 - 242
Frequency, Hz
49.5 – 50.5
Curve form measured by induction of alternating magnetic field
sinusoidal with
harmonics coefficient
up to 5 %
 
    Technical characteristics
     Measurement ranges and their corresponding limits of  basic acceptableerror values ​​ in normal using conditions are shown in Table 2.
 
     Table 2
Type ofmeasuring value
Measurementrange,mT
Acceptablebasic error limit,%
Constant magnetic field Induction
Radial component
0 - 19.99mT
±[0.5+0.5(|Bk / Bx|-1)]
0 - 199.9mT
0 - 1500mT
Axialcomponent
0 - 19.99mT
±[2.5+2.5(|Bk / Bx|-1)]
Radial componentRMS value of alternating magnetic field induction
0-199mkT
±[6+6(|Bk / Bx |-1)]
0 - 1.99mT
±[4+4(|Bk / Bx |-1)]
0 - 19.9mT
0 - 100mT
 
Bk - final value of specified measurement range;
Bx - measured value.
Frequency ranges of alternating magnetic field measured induction are shown in Table 3.
 
     Table 3
Final value ofmeasuring range
Normalfrequency range, Hz
Workingfrequency range, Hz
199mkT
45 - 55
45 - 1000
1.99mT; 19.9mT; 100mT
45 - 55
-
 
Normalworkingconditions are shown inTable 4.
 
Table 4
Influence value
Normal value(normal value range)
Ambient temperature, ° C
20±5
Relative humidity, %
30-80
Atmospherepressure, kPa (mmHg)
84-106.7(630-800)
Frequency, Hz
50±0.5
Frequency ofmeasuredmagnetic field, Hz
45-55
Alternating current voltage supply, V
220±4.4
Curve form of ACpower supply
Sinusoidal withharmonics coefficient up to 5 %
External constant magnetic field
Earth magnetic field
Curve form of alternating magnetic field of measured induction
Sinusoidal withharmonics coefficient up to 2 %
 
Teslameters 43205 additional acceptable error limit, caused by ambient temperature changes from normal to maximum working temperatures values​, equal to acceptable basic error limit for every 10 ° Cof temperature changes.
    Acceptable additional error limit caused by changes in alternating magnetic field induction frequency from normal to any value within frequencies working range (table 3), is equal to acceptable basic error limit.
Acceptable additional error limit caused by harmonics coefficient changes of measured signalfrom normal value to value not more than 5%, isequal to acceptablebasic error limit.
Acceptable additional error limit caused by voltage supply changes from normal to any value within working range, is equal to acceptablebasic error limit.
Teslameters 43205 digital reading device indicates: constant magnetic field measuring induction result of 3.5- bit digital reading device;
     Alternating magnetic field measuring induction result of 2.5-bit digital reading device; decimal point position;
"-" sign in negative polarity of constant magnetic field measuring induction, in positive polarity sign is not
indicated.
     Note. Magnetic induction measured value is accepted positive if magnetic induction vector is directed into measuring probe plane at marker thread (for PIP-PAD) or measuring probe (for PIP-AKC). In PIP-PAD marking label indicates transmitter location Hall probe. In PIP-AKC converter Hall is located in probe back side.
Operation mode setup time is less than 30 minutes.  Teslameters 43205  settling reading time is less than 3 seconds. Devices continuous operating time is 8 hours with 1h break for re-enable. Power supply is not more than 30 VA.
    
Devices case dimensions 380x317x133 mm.
    
Dimensions with hand carrying 380x341x180 mm. Weight of device is not more than 8 kg.
    Device in any measuring ranges stands for 1 min. overload, whose value does not exceed final value subsequent measurement range, but not more than 120% from final value
of max measurement ranges.
     Teslametr 43205
are restored, single-function. Mean time between failures is at least 3000 hours, set-failure operating time is at least 300 hours.
Failure criteria: basic error output out of acceptable limits. Average time restoring efficient condition is not more than 24 hours. Full average lifetimeis not less than 8 years.
Specified service life is at least 4 years. Criteria for limiting condition: technical and economic inadvisability of manufacturing repair (restoration), if direct repair costs exceed price of device.
Device contains following quantity of precious metals:
Gold - 0.466 g;
Silver - 3.625 g.

Photos 43205

43205 teslameter device image.
43205 teslameter device image.
43205 teslameter front view.
43205 teslameter front view.
43205 teslameter side view.
43205 teslameter side view.
43205 teslameter rear view.
43205 teslameter rear view.
43205 teslameter overhead view.
43205 teslameter overhead view.
43205 teslameter bottom view.
43205 teslameter bottom view.


Яндекс цитирования