Teslameters universal 43205/1

Also, this device can be called: 43205-1, 43205 1.

 

43205/1 teslameters universal is intended to measure the radial component of the DC magnetic field induction, RMS value of sinusoidal alternating magnetic field, and the axial component of the static magnetic field induction.

Measuring ranges:

- the radial component of the magnetic field induction, DC - from 0 to 1600 mT;

- axial component of the magnetic field induction, DC - from 0 to 19.99 mT;

- the radial component of the RMS value of the AC induction magnetic field - from 0 to 199 mT.

 

Teslameters 43205/1 performed measurements with the primary converters PEP-RAD and PEP-AKC.

 

Specifications 43205/1:

 

Measurement ranges and the corresponding limits permitted by the basic error in the normal conditions are shown in table (Bk - end value of measuring range, Bx - measured value):

 

Rhode measurand

Measurement range

Limit of acceptable basic error

Induction of a constant magnetic field

The radial component

from 0 to 19.99 mT, from 0 to 199.9 mT; from 0 to 1600 mT

±(1+1(|Bkх|-1))%

Axial component

0 to 19.99 mT

±(2,5+2,5(|Bkх|-1))%

The radial component of the RMS value of a constant magnetic field induction

from 0 to 199 mT

±(6+6(|Bkх|-1))%

from 0 to 1.99 mT; from 0 to 19.9 mT, of from 0 to 199 mT

±(4+4(|Bkх|-1))%

 

Normal range of frequencies 43205/1 - from 45 Hz to 55 Hz.

Operating frequency range - from 45 Hz to 1000 Hz.

 

Limit of acceptable basic error equal to the limit of acceptable additional error:

- caused by changes in ambient temperature from normal to extreme operating temperatures for every 10° C change in temperature;

- due to changes in the frequency of the alternating magnetic field induction from normal to any value within the working range of frequencies;

- due to changes in the harmonic content of the measured signal from the normal value to a value of not more than 5%;

- due to changes in supply voltage from normal to any value within the workspace.

 

Digital readout device teslameters 43205/1 indicates:

- the result of measuring the induction of a constant magnetic field of 3.5 bits of digital reading device;

- the result of measuring the induction of an alternating magnetic field of 2.5 bits of digital reading device;

- the position of the decimal point;

- "-" Sign for negative polarity of the measured value of the constant magnetic induction field, with positive polarity sign is displayed.

 

Range selection and induction type teslameters - manual.

Determination of polarity induction static magnetic field and its indication - automatic.

Warm-up time - no more than 20 minutes.

Setting time 43205/1 - no more than 3 seconds.

Continuous operation - 8 hours.

Break before restarting - 1 hour.

Power consumption 43205/1 - 24 V·A.

 

Device in any of the measurement ranges stand for 1 min overload, the value of which does not exceed the final value of the subsequent measurement range, but not more than 120% of the final value in the largest measuring ranges.

 

Teslameters restored, single function.

MTBF 43205/1 - not less than 3000 hours.

Installed MTBF - not less than 300 hours.

Average time running again - no more than 24 hours.

Average life - at least 8 years.

Specified service life - at least 4 years.

 

Dimensions:

- case teslameters - 380×317×133 mm;

- unit with carrying handle - 380×341×150 mm.

Weight 43205/1 - no more than 7.2 kg.

 

Operating conditions teslameters 43205/1:

 

Normal:

- ambient temperature - 20±5° C;

- relative humidity - 30% to 80%;

- atmospheric pressure - from 84 kPa to 106.7 kPa (630 mm hg. art. to 800 mm hg. art.)

- supply voltage - 220±11;

- mains frequency - 50 Hz±0,5;

- the shape of the AC mains voltage - sinusoidal curve with a coefficient of non-sinusoidal voltage is not more than 5%;

- external constant magnetic field - the magnetic field of the Earth;

- an external alternating magnetic field - no;

- the shape of the measured induction alternating magnetic field - Sine Wave form factor with no more than 2%;

- the frequency of the measured magnetic field induction AC - 45 Hz to 55 Hz.

 

Workers:

- ambient temperature - +10° C to +35° C;

- relative humidity at +25° C - 80%;

- atmospheric pressure - from 84 kPa to 106.7 kPa (630 mm hg. art. to 800 mm hg. art.)

- supply voltage - from 198 V to 242 V;

- mains frequency - of 49.5 Hz to 50.5 Hz;

- the shape of the measured induction alternating magnetic field - sine wave form factor with no more than 5%.

 

Teslameters 43205/1 certified and listed in the state register of measuring instruments. The devices comply with requirements of the applicable technical specifications under normal use, transportation and storage.

Photos: 43205/1

43205/1 teslameter device image.
43205/1 teslameter device image.
43205/1 teslameter front view.
43205/1 teslameter front view.
43205/1 teslameter side view.
43205/1 teslameter side view.
43205/1 teslameter rear view.
43205/1 teslameter rear view.
43205/1 teslameter overhead view.
43205/1 teslameter overhead view.
43205/1 teslameter bottom view.
43205/1 teslameter bottom view.
43205/1 teslameter diagram of the device.
43205/1 teslameter diagram of the device.


Яндекс цитирования