Combined electrical analogue instrument 43102
 
Combined electrical analogue instrument 43102 is designed to measure DC voltage, rms AC voltage sine wave, DC resistance, speed of the crankshaft of the engine, including engines with non-contact ignition system, and the angle of the closed state of the breaker contacts four-, six-and eight-cylinder engines with electric 12V and negative polarity of the "masses".
 
Specifications: Electrical appliances combined analog devices 43102:
 
The limits of the scale (initial and final values ​​of the measuring range) limits. Allowed values ​​of the basic errors of the device in normal conditions of use (Table 2), the values ​​of current consumption device correspond to the values ​​specified in Table 1;
 
Table 1: Values ​​of the combined unit of consumed electrical analog device current 43102
Measurand
Measuring range (initial and final value)
Maximum permissible inaccuracy
Consumption of no more than
Direct current voltage
0V-2V, 0V-20V, 0V-40V
± 1,5%
0.105 mA
AC voltage
60V-400V
± 2,5%
0.510 mA
DC Resistance
0 k = 0, 1 k, 0 k, 100 k
± 2,5%
0.16 mA
Rotational speed of the engine crankshaft
0min 1500min -1, -1, -1 0min-9000min -1
± 2,5%
15mA
The angle of the closed state of the breaker contacts
0 º -45 º, 0 º -60 º, 0 º -90 º
± 2,5%
15mA
 
Table 2 Limits. Allowed values ​​of the basic errors of the combined unit of electrical analogue instrument 43102 in normal conditions of use
Influence quantity
Average value (range)
AMBIENT TEMPERATURE
20 º C ± 5 º C
Regulations
Horizontal ± 2 º
The orientation of the device (relative to Earth's magnetic field)
any
An external magnetic field
Geomagnetic field
An external electric field
The virtual absence of
Relative air humidity :
30% -80%
Atmospheric pressure
84kPa-106, 7kPa (630mm.rt.st.-802mm.rt.st.)
Frequency of measured voltage
45Hz-65Hz
The shape of the measured AC
Sinusoidal with THD less than 2%
Power supply circuit ohmmeter
1.35 In-1 65V
The power supply voltage measuring circuit speed of the engine crankshaft and the angle of the closed state of the breaker contacts
10.8 V-15, 0V
Ferromagnetic ground
-
The coefficient of the variable component of the DC voltage
no more than 3%
 
The limits of acceptable basic and additional errors in the combined unit of electrical analogue instrument 43102 expressed in the form of error given by the formula:
 
γ = ± ((100 ∙ Δ) / X)
 
where Δ - the absolute error, X - normalizing value.
Normalizing values ​​are given in determining the errors are:
- When measuring DC and AC current, frequency, engine speed and the angle of the closed state of the breaker contacts - a finite value of the measurement range;
- When measuring the DC resistance - the entire length of the scale, with a minimum of:
- 46mm - for measuring range 0 k, 100 k;
- 54mm - for measuring range 0 MW-100 MW;
The limits of permissible values ​​of the combined instrument additional errors electrical analogue instrument 43102 due to the slope of the device by 10 ° in any direction from the changes of ambient temperature for each 10 ° C does not exceed the limit of acceptable basic error;
The limit of permissible values ​​of additional errors from the influence of external DC and AC sinusoidal magnetic field with induction 0.5 mT do not exceed ± 1,5%;
The limits of permissible values ​​of the combined instrument additional errors electrical analog device is less than half the 43102 limit of acceptable basic error when installing the device on the basis of ferromagnetic thickness of 2 mm ± 0,5 mm and placed under the influence right up to him a similar device to this is at a distance of at least one m;
Limit of acceptable additional error of the instrument caused by the deviation of the voltage curve of the normal value under the influence of the 2nd, 3rd or 5th harmonic component is equal to 5% of the rms value of the measured voltage does not exceed ± 5%; '
Operation mode setup time unit combined analog electrical appliance 43102 - 1 minute;
Continuous operation of the device in the range of measurements that do not require power supply - 16 hours with a break to re-enable at least 1 hour;
Continuous operation in the range of measurements that require the power supply is determined by the rated capacity of these sources and consumption of the device, but not more than 16 hours;
Operating conditions of the instrument combined electrical analogue instrument 43102:
- Ambient temperature - 1 º C to 40 ° C;
- Relative humidity - 80% at 25 ° C;
Extreme conditions of transportation:
- Ambient temperature - from -50 º C to +50 ° C;
- Relative humidity 98% at 35 ° C;
Atmospheric pressure - 84kPa-106, 7kPa (630mm.rt.st.-802mm.rt.st.);
Mechanical effects - shock acceleration up to 30 m / s 2 with the number of beats per minute, 80-120;
Overall dimensions of the unit combined analog electrical appliance 43102 - 160x120x60mm;
Weight - not more than 0.7 kg;
The manufacturer guarantees the quality of the instrument combined electrical analogue instrument 43102 technical requirements specifications, subject to the consumer the terms and conditions of storage, transportation, installation, operation, established specifications and operational documentation.