Selsyns, rotary transformers, electric motors >> transformers rotating >> 3VT

3VT-2TV-5 Transformer 3W-2TV-5 rotating.

3VT-2TV-5

For order is possible effectively delivery of any quantity.
Transformer 3VT-2TV-5 rotating (3VT2TV5, 3W 2TV 5, 3bt-2tb-5, 3-VT-2TV-5, 3, BT-2TV-5, 3-BT 2TV-5, 3 VT2TV-5, 3 - BT-2TV5, 3-VT-2TV 5 3 W 2TV-5, 3 VT2TV-5, 3, BT-2TV5, 3 BT-2TV 5, 3bt2tb5, 3bt 2tb 5, 3-bt-2tb-5, 3, bt- 2tb-5, 3-bt 2tb-5, 3-bt2tb-5, 3-bt-2tb5, 3-bt-2tb 5, 3 bt 2tb-5, 3 bt2tb-5, 3, bt-2tb5, 3 bt-2tb 5)
 
Transformer 3VT-2TV-5 rotating intended for use in electro-mechanical computing devices, servo systems, as well as the primary sensor to digital converters.
Depending on the scheme and the inclusion mode (function) transformers are divided into sine-cosine (Synchro), output voltage which is proportional to the sine (cosine) the angle of rotation of the rotor, and linear (LVT), the output voltage which varies linearly proportional to the angle within ± 60 °.
In non-contact rotary transformer POWER COLLECTION by means of ring transformer, which ensures high reliability products.
Depending on the scheme and the inclusion mode (function) transformers can be:
- Sine-cosine (Synchro), output voltage which is proportional to the sine (cosine) the angle of rotation of the rotor;
- Linear (LVT), the output voltage which varies linearly - in proportion to the angle of rotation of the rotor within ± 60 °;
- Sensors in transformer for remote transmission (TPD-H);
- Receivers in a transformer for remote transmission (TPD-P);
- Differential transformer sensors in remote transmission (TPD-DD).
Operation - Synchro;
 
Technical characteristics of the instrument transformers 3VT-2TV-5 rotating :
 
Ambient temperature - -60 ° C to +85 ° C;
Relative humidity - up to 98% at 40 ° C;
Shock instrument transformer 3VT-2TV-5 rotating - 118m / s 2;
Vibratory loads at up to 200Hz and acceleration 59m / s 2;
Input impedance idling - 200 ohms;
Rated voltage transformer unit 3VT-2TV-5 rotating - 12V;
The conversion coefficient unit - 0.560;
The change of ratio when the ambient temperature at 40 ° C - 0.5%;
Changing the transformation of the instrument transformer 3VT-2TV-5 rotating voltage changes - 0.2%;
Rotary transformers 3W-2TV-5 are divided into accuracy classes:
- Transformer 3VT-2TV-5 1, accuracy class (1st class. T) has the characteristics:
- Accuracy in repetition TPD - ± 5ugl.min.;
- Asymmetry of null positions of the rotor - ± 2ugl.min;
- Error display the sine function - ± 0,05%;
- Residual EDS - 0.40%;
- Transformer 3VT-2TV-5 Class 2 accuracy (2 cl. T) has the characteristics:
- Accuracy in repetition TPD - ± 10ugl.min.;
- Asymmetry of null positions of the rotor - ± 3,5 ang;
- Error display the sine function - ± 0,1%;
- Residual EDS - 0.40%;
- Transformer 3VT-2TV-5 grade 3 of accuracy (3 cl. T) has the characteristics:
- Asymmetry of null positions of the rotor - ± 7ugl.min;
- Error display the sine function - ± 0,2%;
- Residual EDS - 0.40%;
Outside diameter - 25mm.
Weight of the device rotating transformer 3VT-2TV-5 - 0.115 kg;
Minimum time - 5000ch.