Equipment for maintenance checkup >> - the list of equipment for vehicle inspection >> gas analyzers >> other gas analyzers

121FA-01

27 999 RUB
11 200 UAH
available:
12 pieces

Online prices include VAT.

For order is possible effectively delivery of any quantity.

Gas analyzer 121FA-01 (121FA01, 121 FA 01)

Gas analyzer 121FA-01 - a device used for the selection, transportation, training exhaust gasoline engines n measurements of the volume fraction of carbon monoxide in the gas sample.
Ranges volume fraction of carbon monoxide from 0 to 5% and 0 to 10%.
The composition of the analyzed gas mixture inlet conduit in volume proportions are:
    - Carbon dioxide - 12%;
    - Nitrogen oxide - up to 1.6%;
    - Carbon monoxide - 10%;
    - Acetaldehyde - up to 0.02%;
    - Methane - 0.8%;
    - Nitrogen - 70%;
    - Oxygen - 20%;
- Oxygen - 5%
     - Water vapor - 0.1 kg/m3 - 0.16 kg/m3.
Nominal power consumption of the gas analyzer, no more:
- When the power flow booster - DC 15W, 25W AC-coupled;
- When the stimulus rate - DC 19W, 30W AC-coupled.
The insulation resistance between the power plug for power supply and enclosure gas analyzer: 20MOm (at ambient temperature (20 +5) ° C and relative humidity up to 85%).
Flow assay mixture produced stimulus flow: not less than 0.06 m3 / y
Power supply: 220 ± 33V, 50 ± 1 Hz, 12 ± 1,2 V.
Dimensions: 356 × 267 × 148mm.
Weight: 5.75 lbs.

Drawings analyzer 121FA-01:
 
121ФА-01 блок-схема
 
Flowchart analyzer:
    1 - emitter, 2 - measuring cell, 3 - obturator, 4 - interference filter, 5 - flange, 6 - radiation receiver, 7 - pre-amplifier, 8 - indicating instrument, 9 - secondary processing unit, 10 - power supply to the converter voltage 11 - Optoelectronic pairs, 12 - electric motor.
 
121ФА-01 Чертеж преобразователя первичного

The drawing of the primary converter:
    1 - Board Ro5.064.859 2 - Screen 3 - housing, 4 - cover, 5 - Bush 6 - motor, 7 - pulley, 8 - bearing Kochenov 9 - axis, 10 - Pulley 11 - Glass, 12 - heating element, 13 - a nut, 14 - transmitter, 15 - ditch; 17 - obturator, 18 - interferetsionny filter, 19 - flange, 20 vacuum lubricant, 21 - a radiation detector; 22 - Ra5.064.890 fee.; 23 - screen.
 
121ФА-01 Чертеж трубопровода

Pipe Drawing analyzer 121FA-01:
    1 - adapter, 2 - flexible tube, 3 - Clip 4 - pen 5 - connector, 6 - housing.
 
121ФА-01 Побудитель расхода газа П2

Stimulus flow rate P2:
    1 - suction valve, 2.5 - housing, 3.4 - ROM, 6.9 - nut; 7.15 - friction gear 8 - Shaft, 10 - Motor 11 - bush, 12 - flange, 13 - membrane; 14 - valve discharge; 16.17 - screw.
 
121ФА-01 Фильтр

Filter analyzer:
    1 - sump, 2 - socket, 3 - housing, 4 - coarse filter, 5 - socket, 6 - nut 7 - Filter 8 - box 9 - Washer, 10 - net 11 - a lock ring.
 
121ФА-01 Схема расположения элементов конструкции в преобразователе
 
    Arrangement of structural elements in the transducer measuring:
    1 - primary converter, 2 - voltage converter, 3 - power supply, 4 - TNI block, 5 - flow booster, 6 - masks, 7 - housing, 8 - handle.
    Specifications 121FA-01
    Gas analyzers 121FA-01 allow the inaccuracy, the value of which does not exceed:
    - Measuring range from 0 to 6% ± 0,2
    - For the range from 0 to 10% ± 0,4.
    Also gas analyzers 121FA-01 have additional error of indication, expressed in volume caused by the change of one of the influencing factors other conditions remaining unchanged for the measurement range of 0 to 6% are in the range:
    - When the temperature changes over the operating range of ± 0,1% for every 10 ° C;
    - When the pressure of the environment over the entire operating range of pressure for every 3.3 kPa - ± 0,24%;
    - Changing the volume fraction of carbon dioxide from 0 to 12% - 10.05%.
    For 121FA-01 limits of acceptable change her testimony at regulated time period for a range of 0 to 5% must comply with:
    - For the lower detection limit (drift "0") - ± 0,06% in 1 hour;
    - For the upper limit of measurement (sensitivity drift) - ± 0,1% in 24 hours.
    Gas analyzer 121FA-01 refers to recoverable, maintainable, and single-channel difunctional products. The unit packaged for transport withstand without damage:
    - The impact of ambient temperature from -45 ° C to +50 ° C;
    - The impact of the relative air humidity up to 98% at 35 ° C;
    - The impact of transport shaking with acceleration 30m/g2 and frequency from 80 to 120 beats per minute.
    Gas analyzer 121FA-01 withstand increased carbon monoxide in the sample up to 13% within 30 minutes. Time to restore normal operation of the device after an overload of not more than 2 hours. Warm-up time no more than 20 minutes.
    Mean time to failure of the device 121FA-01 for at least 20,000 hours (100,000 measurements), which corresponds to the probability of failure-free operation is not less than 0.95 per 1000 hours. Average yield to the average repair analyzer for at least 8,000 hours (40,000 measurements). Average life of the gas analyzer at least 8 years. Installed failure operating time is not less than 1600 hours (8000 intentions).
    Fixed a resource analyzer at least 2500 hours (12500 intentions). Mounted storage life of at least 0.5 years until the product is in operation.
    Operating conditions 121FA-01
    Gas analyzer 121FA-01 meets the conditions of climatic execution 7X1 4 according to GOST 15150-69 and operates under the following conditions:
    - Ambient temperature - from 0 to 45 ° C;
    - Relative humidity: - 98%;
    - Atmospheric pressure environment - from 86.4 kPa to 104.6 kPa;
    - Manufacturing the vibration amplitude of 0.1 mm and a frequency of 25Hz.
    Operating position analyzer 121FA-01 - horizontal, with a tolerance of ± 5 °.
    Exhaust gas temperature at the inlet of the unit duct - 200 ° C.

Photos: 121FA-01

121FA-01 device image.
121FA-01 device image.
121FA-01 front view.
121FA-01 front view.
121FA-01 side view.
121FA-01 side view.
121FA-01 back view.
121FA-01 back view.
121FA-01 top view.
121FA-01 top view.


Яндекс цитирования