Transformer 10VTM-B-10P rotating (10VTMB10P 10-TMV-B-10P, 10 TMV B 10P, 10VTM-B10P, B10P 10VTM, 10VTMB-10P, 10P 10VTM 10 TMV-B-10P)
 
Rotary transformers 10VTM-B-10P is a two-pole contact four wrap machine.
Depending on the scheme and the inclusion mode (function) devices rotating transformer 10VTM-B-10P divided into sine-cosine (Synchro), output voltage which is proportional to the sine (cosine) the angle of rotation of the rotor, and linear (LVT), the output voltage which varies linearly proportional to the angle of ± 60 °.
 
Technical characteristics of the instrument transformers 10VTM-B-10P rotating:
 
Operation - Synchro;
Nominal frequency of the excitation voltage instrument transformer 10VTM-B-10P Rotary - 400Hz;
Operating frequency range of excitation voltage - 390Gts-510Gts;
Shaft speed instrument transformer 10VTM-B-10P Rotary - 60ob/min;
Moment of static friction - 0.06 Nm;
Supply voltage - 60V;
Input impedance transformer idling device 10VTM-B-10P Rotary - 1000 ohms;
Turns Ratio - 1.000;
Rotary transformers 10VTM-B-10P Synchro mode are divided into accuracy classes:
- Transformer 10VTM-B-10P an accuracy class (1st class. T) has the characteristics:
- Asymmetry of null positions of the rotor - ± 2ugl.min.;
- Error display the sine function - ± 0,06%;
- Residual EDS - 0.33%;
- The difference between the coefficients of transformation - 0.08%;
- Transformer 10VTM-B-10P Class 2 accuracy (2 cl. T) has the characteristics:
- Asymmetry of null positions of the rotor - ± 3,5 ang.;
- Error display the sine function - ± 0,1%;
- Residual EDS - 0.50%;
- The difference between the coefficients of transformation - 0.125%;
- Transformer 10VTM-B-10P Class 3 accuracy (3 cl. T) has the characteristics:
- Asymmetry of null positions of the rotor - ± 6,0 ang.;
- Error display the sine function - ± 0,2%;
- Residual EDS - 0.67%;
- The difference between the coefficients of transformation - 0.2%;
- Transformer 10VTM-B-10P 4 class accuracy (4 cl. T) has the characteristics:
- Error display the sine function - ± 0,3%;
Outside diameter - 56mm;
Weight of the device rotating transformer 10VTM-B-10P - no more than 0.68 kg;
Vibration loads:
- Frequency range - up to 200 Hz;
- Acceleration - 60m / s 2;
Shock - 120m / s 2;
Ambient temperature - -60 ° C to +100 º C;
Relative humidity at 40 ° C - 98;
Warranty life - 1200 hours;
The manufacturer guarantees the quality of the instrument transformer 10VTM-B-10P rotating the technical requirements specifications subject to user terms and conditions of storage, transportation, installation, operation, established specifications and operational documentation. 